Resetting The Duration Countdown Timer - Jacuzzi J - 280 Owner's Manual

J-200 collection
Hide thumbs Also See for J - 280:
Table of Contents

Advertisement

B. Resetting the duration countdown timer (CLEARRAY® System
only)
Once the duration countdown timer for the CLEARRAY System has
reached zero, you will need to reset it, replace the UV bulb and clean the
quartz tube.
To reset the duration countdown timer:
1. Press and hold Jets pump 1 (
time for 3 seconds.
2. Press the Warmer (
3. If the timer has reached "0," pressing the Jets pump 1 (
will reset the timer to 365 days. If the timer is not at "0" pressing
the Jets pump 1 button will not reset it.
Note: If the spa power is interrupted, the duration countdown timer is not
affected. The number of days remaining is stored in the memory and will
continue to countdown once power is regained.
4. If the duration countdown timer is not at "0" and you need to reset it:
a. Press and hold the Jets pump 1 and Cooler buttons at the same
time for 3 seconds.
b. Press the Warmer button to scroll to "U."
c. Press the Jets pump 1 button to switch from "U" to "O3."
d. Press and hold the Jets pump 1 and Cooler buttons at the same
time for 3 seconds.
e. Press the Warmer button to scroll to "O3."
f.
Press the Jets pump 1 button to switch from "O3" to "U." The
timer has been reset to 365 days.
Press
Press
) and Cooler (
1
) button until the display shows "0."
1
) at the same
J-200
) button
1
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J-275J-235J-245J-210J - 230J - 270 ... Show all

Table of Contents