Table 8-2. System Error Codes (Continued)
Error Code
Problem Description
010041
Error detected in Y -axis servo
feedback loop.
010050
Uppermost SIMM indicates a
failure.
010051
Next to uppermost SIMM
indicates a failure.
010052
Both upper and lower SIMMs
indicate a failure.
010080
RS-232-C data overflow.
020001
Firmware problem. Bad
020002
EPROMS.
030000
X-axis shutdown.
030001
Y -axis shutdown.
030002
Y -axis friction too high.
030003
Y -axis failure
030010
Excess friction in pen
capping assembly
04xxxx
MIO interface error.
Corrective Actions
Check encoder strip, carriage assem-
bly, trailing cable, main PCA.
Replace uppermost SIMM.
Replace next to uppermost SIMM.
Replace both upper and lower SIMMs.
Data byte was not read before another
was entered into the UART. Replace
main PCA. If problem remains report
the firmware problem to the HP
Response Center or the nearest HP
Sales and Support Office.
For all 2XXXX errors, report the
firmware problem to the HP Response
Center or the nearest HP Sales and
Support Office. Note conditions
before the error occurred. Include
system configuration in the report.
All 300XX errors indicate a failure of
hardware or electronics of the X- or
Y -Axis. Refer to SERVO CONTROL
SYSTEM FAILURES in this chapter.
Refer to code 030000.
Check mechanical parts in pen cap-
ping assembly for binding.
If an MIO is installed, check the MIO
setup. Then replace the MIO.
Troubleshooting