Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a qualified
technician using Hearth & Home Technologies specified and
approved parts.
1. Converting to LP Gas
NOTE: Gas conversions should only be performed by a
qualified service person, and/or where required by state
and local codes, licensed installer/service technician. In
the Commonwealth of Massachusetts, installation must
be performed by a licensed plumber or gas fitter.
Any damaged valve components should not be installed.
If a valve or regulator has been dropped or appears to
have been modified, the valve or regulator should not
be installed.
KIT CONTENTS:
Replacement orifice; replacement
pilot injector; valve regulator; and conversion label.
TOOLS REQUIRED: Power drill (a 90 degree handle is
helpful); #2 Phillips bit; 5/32 in. Allen wrench; 5/8 in. open
end wrench.
OPEN
Disconnect power and turn off gas supply if
Figure 6.1
installed. Remove front, glass, brick refractory and logs if
installed. (It is only necessary to remove the left brick panel
for burner removal.
Loosen the shutter adjustment wingnut (located underneath
the appliance). It is helpful to remove the nut completely.
Slide the shutter to the right (closed position).
Page 22
Figure 6.2
free from the orifice receiver. Remove from the firebox and
handle with care.
Figure 6.3
Replace with appropriate orifice.
If the shutter disengages from the appliance with the burner
(See Figure 6.2), it must be reinstalled over the orifice prior
to the reinstallation of the burner.
CLOSE
Figure 6.4
allen wrench, remove pilot injector and replace with appro-
priate injector.
Reassemble appliance.
Heat & Glo · Mission Bay · 250-7512F
Lift the burner from the left side and slide left until
With a 5/8 in. wrench remove orifice retaining nut.
PROPANE
.
.0635 (52 DMS)
Remove pilot hood, set aside. Using a 5/32 in.
(35 LP, 62 NG)
NATURAL GAS
.1065 (36 DMS)