Vermont Castings SDDVTEB Homeowner's Installation And Operating Manual page 35

Sddvt/sddvtc series direct vent/natural vent gas heater
Table of Contents

Advertisement

. Use the ON / ▲ button
to set the desired On
Delay Time from 0 to 15
minutes.
3. Use the OFF / ▼ button
to set the desired Off
Delay Time from 0 to 15
minutes.
4. If there is no input within
3 seconds, the new set-
ting will be transmitted to
receiver.
5. The default settings for both transmitter and receiver
are 5 minutes for ON delay time and 8 minutes for OFF
delay time.
Low Battery Detection
Figure 66
1. Battery voltage is checked
once a minute. When the
battery voltage drops to a
certain level, the low-bat-
tery icon will display on
LCD, and the transmit-
ter will turn off the appli-
ance. The transmitter
will not function anymore
until fresh batteries are
installed.
. When the batteries are
low, the LCD displays a low battery indicator. The low
battery indicator will be displayed in any mode.
3. The transmitter will not operate with low batteries.
Change the batteries before the batteries are too weak
for normal operation. Turn the unit OFF before replac-
ing batteries.
Child-Proof Protection
Figure 67
1. Press and hold the ON
and OFF buttons simul-
taneously for three (3)
seconds to enter child
proof mode.
. The transmitter will not
send a signal again until
the childproof mode is
deactivated by pressing
the ON and OFF buttons
simultaneously for three
(3) seconds to exit child
proof mode. The Childproof indicator disappears from
LCD.
30004968
FP146
Fig. 65 Blower time delay
display.
FP2146
blower delay timer
12/08
°F
FP150
Fig. 66 Low battery
display.
FP2150
low battery display
12/08
°F
FP151
Fig. 67 Child protection
display.
FP2151
no child display
12/08
Stardance® Direct Vent/Natural Vent Gas Heater
Transmitter Thermal Shutdown
Figure 68
1. If transmitter measures
a r o o m t e m p e r a t u r e
exceeding 99° F, the LCD
will display "HI" and the
transmitter will turn off the
appliance.
. Transmitter will not func-
tion until the room tem-
perature has dropped
below 99° F. If transmitter
measures a room tem-
perature less than 40° F,
the LCD will display "LO" and NO SIGNAL will be sent
to turn on the appliance.
Receiver
Slide Switch
1. ON position: The main burner will ignite and blower will
come on when blower on delay time is reached and
fan speed has been enabled, the flame height is max;
otherwise just burner will ignite until the slide switch is
placed in the OFF or RS position to turn burner off.
. RS position: The system will only operate if the remote
receiver receives a signal from the transmitter.
3. OFF position: The system is off. If fan speed has been
enabled, blower will continue to operate until OFF delay
time expires. The slide switch should be placed in the
OFF position if you will be away for an extended period
of time. If the remote receiver is mounted out of reach
of children, the OFF position also functions as a safety
device by both turning the system off and rendering
the receiver inoperable.
Optional 6 Hour Shutdown
1. The receiver comes preset from the factory with a 6
hour shutdown from its last ON or flame lower opera-
tion. This is done to prevent the appliance from con-
tinuing to operate if unattended.
. You may disable this feature if you wish. To disable,
change the receiver privacy (DIP) switch #1 ONLY to
the OFF position. Make sure the transmitter privacy
(DIP) switches are set the same as the receiver. Follow
the instructions on how to set the privacy (DIP) switch
setting.
3. By disabling this feature, your appliance may continue
operating unattended.
FP15
Fig. 68 Thermal shutdown
display.
FP2152
thermal shutdown display
12/08
35

Advertisement

Table of Contents
loading

Table of Contents