Install The Vent Pipe; Install The Log Set - Vermont Castings SDDVTEB Homeowner's Installation And Operating Manual

Sddvt/sddvtc series direct vent/natural vent gas heater
Table of Contents

Advertisement

Stardance® Direct Vent/Natural Vent Gas Heater
For U.S. installations: The venting system must con-
form with local codes and/or the current National Fuel
Gas Code, ANSI Z.1.
For Canadian installations: The venting system must
conform to the current CSA B149.1 installation code.

Install the Vent Pipe

Apply a bead of sealant around bottom end of inner
starter pipe (found in bag with logset) and attach to
stove. Apply a bead of sealant around top of inner
starter pipe and install the Z31B00 FSDHAG Draft Hood
according to Draft Hood instructions. (Fig. 45)
Attach the first section of venting to the draft hood. De-
pending on the length of the individual venting sections
and the lengths of the decorative pipe (if installed), you
may need to slip the decorative pipe over the venting
sections before attaching upper sections to lower ones.
The sections of decorative pipe should be oriented with
their seams (if any) toward the wall; sections usually
do not need to be fastened at each joint, other than
slip sections. If the layout includes a slip section, this
should be the last section of pipe visible in the room, at
the ceiling. Complete the venting according to the vent
maker's instructions.
CAUTION: Before installation, inspect ember bed
burner for damage. Do not use ember bed if damaged
or cracked. NOTE: Small, shallow surface cracks are
acceptable.
1. Remove the logs from their packaging and inspect
each piece for damage. DO NOT INSTALL DAM-
AGED LOGS.
. Install the rear log by mating
the notch on the bottom of
the log with the raised notch
on the back left side of the
ember bed. (Fig. 47) Ensure
the cutout in the right side of
the log is sitting around the
pilot assembly and pilot is
not obstructed. (Fig. 46)
6
Fig. 45 Decorative 7" pipe may be fitted around the B-vent
pipe.

Install the Log Set

Figure 46
Decorative
7" Pipe
4" B-vent
Pipe
Draft Hood
Adapter
ST358
Decorative
pipe around b-vent
4/26/00 djt
Rear Log
MHSC Direct Vent
System may be
used after Draft
Hood up to the
ceiling
ST358
LG493
30004968