Transmit Power Limiter; Meter; Changing The Meter Type - Kenwood TS-990S Instruction Manual

Hf/50 mhz transceiver
Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

4 BASIC OPERATIONS

TRANSMIT POWER LIMITER

You can place a limit on the transmit power of your
transceiver. This function prevents the transmit power
from exceeding the configured transmit power limit even
with further rotation of the PWR control. You can also set a
different transmit power limit for the DATA mode.
1 Press [MAX-Po] (F) to open the TX Output Limit
screen.
2 Press [
] (F4) or [
for a frequency band.
3 Press [
] (F2) or [
transmit power to be controlled.
As shown below, you can select the item to limit the transmit
power.
Max Power Limit
Transmit power limit for normal transmission.
Max Power Limit (DATA)
Enables the configuration for the transmit power limit while in DATA
Mode.
TX Tune Power
Enables the configuration for the transmit power limit for the
TX Tuning.
{page 9-14}
4 Press [-] (F6) or [+] (F7), or rotate the MULTI/CH
control to select the limit value for the transmit power.
Press and hold [(RESET)] (F1) to revert the limit value for the
selected item to the default.
5 Press [MAX-Po] (F) or [ESC] to exit.
Note:
◆ If "On" (with the 5 W transmit power reduction enabled) is
configured in Advanced Menu 08, "TX Power Down with
Transverter Enabled", [MAX-Po] (F) on the right side of the main
screen and the wattage value on the key guide will disappear when
the transverter or drive-out is activated.
◆ If ANT1 is selected for the transceiver for use with an external
antenna tuner, the maximum transmit power is limited to 100 W.
Even if greater than 100 W is configured for the transmit limiter, the
display on the key guide of [MAX-Po] (F) remains as 100 W as well
as the display on the main screen (100 W).
4-18
] (F5) to highlight a line
] (F3) to select the

METER

The meter for the main band displays the signal as an
S-meter while receiving and as the selected meter while
transmitting. The meter for the sub band always displays
the readout of the S-meter. The meter type for the main
band displayed on the main screen can be changed.

CHANGING THE METER TYPE

You can select the meter display pattern, showing the
main band status, from a digital pattern or two analog
patterns.
1 Select Group No. 0, "Basic Configurations", from the
Menu screen.
2 Access Menu 10, "Meter Display Pattern".
3 Press [SELECT] (F4) to allow editing of the parameter
box.
4 Press [-] (F4) or [+] (F5) to select "Type 1" (Digital),
"Type 2" (Analog 1), or "Type 3" (Analog 2).
The default is "Type 2" (Analog 1).
5 Press [
] (F1).
6 Press [MENU] to exit.
Type 1 (Digital Meter)
Index
Contents

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents