Command/Response Table; Universal Sw Control Program; Installing The Software; Using The Software - Extron electronics YCS SW6 MX User Manual

Y/c separator switcher
Hide thumbs Also See for YCS SW6 MX:
Table of Contents

Advertisement

Serial Communication, cont'd
Symbol definitions
= CR/LF (carriage return/line feed)
• = Space
= Input number 0 – 6 (0 = Muted output)
X1
= Software version x.xx
X2
= Format
X3
0 = Muted output, 5 = NTSC/composite video,
6 = NTSC/S-video, 7 = PAL/composite video,
8 = PAL/S-video

Command/response table

Command description
Select input channel
Select input channel
X1
Example:
Select input channel
(audio)*
X1
Example:
* If an audio/video switcher is chained to the RS-232 port of the YCS SW6 MX,
use this command to break the audio signal away from the video signal.
Request information
Example:
Current input - input 2, NTSC/S-video; software version = 1.23; and maximum
number of inputs = 6.
Request part number
Example:
Query software version
Example:
YCS SW6 MX • Serial Communication
3-4
ASCII
Response
&
C
X1
X1
5&
C5
!
C
X1
X1
2!
C2
I/i
V
•T
•QVER
•M6
X1
X3
X2
I
V2•T6•QVER1.23•M6
N/n
Nxx-xxx-xx
N
N60-224-01
Q/q
QVER
X2
Q
QVER1.23

Universal SW Control Program

The Universal SW Control Program, Extron part number
29-031-01, which ships with the YCS SW6 MX switcher, is
compatible with Windows 3.1, 3.11, 95/98, and NT. It provides
remote control of input selection.

Installing the software

The Universal SW Control Program is contained on a single 3.5"
diskette, and it can run from the floppy drive. However, it is
usually more convenient to load and run the program from the
hard drive.
To install the software from the floppy disk onto the hard drive,
run SETUP.EXE from the floppy disk, and follow the
instructions that appear on the screen. The program occupies
approximately 1 MB (megabyte) of hard disk space.
By default, the Windows installation creates a C:\UNIVSW
directory, and it places two icons (Universal Switcher Control
Pgm and Universal Switcher Help) into a group or folder
named "Extron Electronics".

Using the software

To run the software, do the following:
1.
Double-click on the Universal Switcher Control Pgm icon
in the Extron Electronics group or folder.
The Comm menu appears on the screen.
2.
Click on the comm port that is connected to the switcher's
RS-232 port.
The Universal SW Control Program window appears
(figure 9, on the next page). It displays the current input
selection.
3.
Using normal Windows controls, you can perform the
same adjustments as from the front panel.
YCS SW6 MX • Serial Communication
3-5

Advertisement

Table of Contents
loading

Table of Contents