Arm; Count - HP E1366A User Manual

Hewlett-packard rf multiplexers user's manual
Table of Contents

Advertisement

ARM

Subsystem Syntax

:COUNt

Parameters
Comments
Example
Chapter 5
The
subsystem selects the number of scanning cycles (1 through
ARM
32767) for each
INITiate
ARM
number
:COUNt <
> MIN | MAX
:COUNt? [MIN | MAX]
ARM:COUNt <number> MIN | MAX
multiple of times (1 to 32767) with one
INITiate:CONTinuous OFF |0
cycles.
Parameter Name
<number>
Number of Scans: Use only values between 1 to 32767 for the
number of scanning cycles.
Related Commands:
*RST Condition:
Setting Ten Scanning Cycles
This example sets an RF multiplexer for 10 scans of channels 00 through
03. When the scan sequence completes, channel 03 is closed.
ARM:COUN 10
SCAN (@100:103)
INIT
HP E1366A/E1367A RF Multiplexers Command Reference
command.
allows scanning cycles to occur a
INITiate
command when
is set.
MIN
sets 1 cycle and
Parameter Type
numeric
ABORt
,
INITiate:IMMediate
ARM:COUNt 1
! Set 10 scans per INIT command
! Scan channels 00-03
! Start scan, close channel 00
MAX
sets 32767
Range of Values
1 |32767 |MIN |MAX