Listing And Code Approvals; Appliance Certification; Gas Pressure Requirements; High Altitude Installations - Heat & Glo 350TRSI-AUF Owner's Manual

Hide thumbs Also See for 350TRSI-AUF:
Table of Contents

Advertisement

1

Listing and Code Approvals

A. Appliance Certification
MODELS: 350TRSI-AUF, 350TRSILP-AUF
LABORATORY: SAI Global
TYPE: Gas Space Heating Appliance
STANDARD: AS4553:2008
The Heat & Glo gas appliances discussed in this Installer's
Guide have been tested to certification standards and listed
by the applicable laboratories.
This appliance must be installed in accordance with the
rules in force.
NOX Class 5 for G20, NOX Class 5 for G31
B. Gas Pressure Requirements
WARNING! Risk of Explosion! An in-line regulator
MUST be installed if the gas pressure exceeds 3.7 kPa.
Failure to install a regulator could damage valve.
Pressure requirements for 350TRSI-AUF and 350TRSILP-
AUF fireplaces are shown in table below.
Two taps are provided on the right hand side of the gas
control for a test gauge connection to measure the inlet
and outlet pressures.
The fireplace and its individual shut-off valve must be dis-
connected from the gas supply piping system during any
pressure testing of the system at test pressures in excess
of 60 mbar or 6 kPa.
If the fireplace must be isolated from the gas supply pip-
ing system by closing an individual shut-off valve, it must
be of the handle-less type.
Inlet Gas Pressure
Outlet (Manifold) Gas Pressure
Maximum Gas Consumption
Burner Injector
Pilot Injector
An in-line regulator MUST be installed if the gas pressure exceeds 3.40 kPa. Failure to install a regulator could damage
valve.
10
Natural Gas
1.13 - 3.40 kPa
.80 - .95 kPa
DMS 44 (2.18 mm)
Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. o • 6/12
C. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 ft. (610 m) elevation:
Reduce input rate 4% for each 1000 ft. (305 m) above
2000 ft. (610 m).
D. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
E. Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
and burn, whether flame proofed or not, or plastered or
unplastered shall be considered combustible materials.
F. Electrical Codes
All electrical safety testing has been done following the EN
60335-2-102 standard. Local codes apply.
21 MJ/h
.0181
Propane
2.75 - 3.40 kPa
2.36 - 2.61 kPa
19.8 MJ/h
DMS 55 (1.32 mm)
.0121