Function Key Programming Overview (∗57 Menu Mode); Programming Function Keys - Honeywell ADEMCO VISTA-10P Installation And Setup Manual

Hide thumbs Also See for ADEMCO VISTA-10P:
Table of Contents

Advertisement

Installation Instructions
Function Key Programming Overview (∗ ∗ ∗ ∗ 57 Menu Mode)
The system provides the ability to program each of the four keypad function keys to perform one of 12
system operations. The end user can then activate the function by simply pressing and holding the
programmed key for 2 seconds. Typical functions (listed below) include single-button arming, turning
lights on/off, or single-button paging.

Programming Function Keys

Function key programming involves:
1. Assigning the function key number;
2. Selecting the desired function for that key.
Start Function Key Programming mode by pressing
following prompts are displayed:
PROMPT
Press Key to Pgm
0 = Q u i t
0
Key "A" Func
Zone 95
00
5-10
VALID ENTRIES
Press the desired function key, A-D.
NOTE: A key programmed as a function key
is no longer available to be used as an end-
user macro key or panic key.
[∗] to continue
Enter the desired function for this key:
00 = For the Function key selected, the function will be as follows (system default):
If A selected = Zone 95 (emergency key, same as [1] [∗] pair)
If B selected = Zone 99 (emergency key, same as [∗] [#] pair)
If C selected = Zone 96 (emergency key, same as [3] [#] pair)
If D selected = Single-button paging
01 = Single-button paging (sends a 999-9999 message to pager)
02 = Display time
03 = Arm AWAY (reports as User 00 if closing reports are enabled)
04 = Arm STAY (reports as User 00 if closing reports are enabled)
05 = Arm NIGHT-STAY (reports as User 00 if closing reports enabled)
06 = Step Arming (arms STAY, then NIGHT-STAY
07 = Output Device Command (for device programmed as system operation type 66 in *80
Menu Mode)
08 = Communication Test (sends Contact ID code 601)
09=
Macro Key (defined by [#] [6] [6] command)
[∗] to continue; returns to key number prompt with the next function key letter displayed.
† If Night-Stay zones are listed in zone list 5
57 while in Data Programming mode. The
EXPLANATION
A
B
C
D
, then AWAY)
1
2
3
OFF
AWAY
STAY
4
5
6
TEST
BYPASS
MAX
7
8
9
INSTANT
CODE
CHECK
0
#
*
READY

Hide quick links: