Zone List Overview (∗81 Menu Mode); Zone List Programming - Honeywell ADEMCO VISTA-10P Installation And Setup Manual

Hide thumbs Also See for ADEMCO VISTA-10P:
Table of Contents

Advertisement

Zone List Overview (∗ ∗ ∗ ∗ 81 Menu Mode)
Zone lists let you group individual zones for use with certain system actions. The following table
shows the available zone lists and their purposes:
List No.
Used for...
1, 2
general purpose
3
chime-by-zone
4
cross zones
5
night stay zones
6
general purpose
VISTA-10PSIA
7
general purpose
VISTA-10PSIA
8
general purpose
9
zones that activate Pager 1

Zone List Programming

Zone List programming involves:
1. Selecting an appropriate zone list number;
2. Adding the desired zone numbers to be included in that list.
Start Zone List Program Mode by pressing
prompts are displayed :
*81 Menu Mode
PROMPT
Zone List No.
(00 = Quit)
01
01 Enter Zn Num.
(00 = Quit)
00
01 Del Zn List?
0 = No 1 = Yes
0
01 Delete Zone?
0 = No 1 = Yes
0
01 Zn to Delete?
(00 = Quit)
00
NOTES:
• Any list may include any or all of the system's zone numbers.
• A zone list can be assigned to more than one output relay.
• When creating zone list 4 for cross zoning, include only zones assigned to zone types 3, 4, or 5. Do
not include zones that have delays (entry/exit zones, interior w/delay) or 24-hour zones, as these
zone types may produce unpredictable operation and may not function as intended.
Cross Zone Timer option.
• Zone List 6: VISTA-10PSIA: See field *50 for Dial Delay Disable option.
• Zone List 7: VISTA-10PSIA: See field *93 for Unlimited Reports option.
: dial delay disable
: unlimited reports
81 while in Data Programming mode. The following
VALID ENTRIES
Enter the Zone List Number to program (or 00 to end these entries).
01-09 = zone list number
[∗] to continue
Enter each zone number followed by [∗] to add each zone to the zone list.
01-06 = wired zones; 09-24 = wireless zones; 49-56 = button zones
91 = addr. device report enable (Enter a report code for zone 91 to enable addressable device
reporting.
92 = duress report enable (Enter a report code for zone 92 to enable duress reporting)
95, 96, 99 =emergency zones
00 to continue
IMPORTANT: Do not include fire zones in zone lists that are used to STOP device actions.
To delete the zone list, enter 1. All zones in the zone list will be deleted automatically and
the system returns to the Zone List No. prompt.
To save the zone list, enter 0.
[∗] to continue
To save the entire zone list, enter 0 and the system returns to the Zone List No. prompt.
To delete a zone or zones in a zone list enter 1 to continue.
[∗] to continue
Enter each zone to be deleted from the list followed by [∗] to accept each zone.
01-64 = zones to be deleted from list
00 when done to return to the Zone List No. prompt
EXPLANATION
See field *85 for
5-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-10psia

Table of Contents