The 4285 and 4286 modules are UL Listed only for use on residential fire and UL residential burglar alarm
installations.
Phone Module Problems
If no touch tones are produced following access to the security system from on-premises (this problem
may arise in rare cases), it may be necessary to reverse the wires connected to terminals 3 and 4 on
the phone module and the wires connected to terminals (21) & (22) on the control. The wiring
diagram shows the wiring connections that will provide proper operation in most cases.
Connection to the incoming telco line via a RJ31X jack and direct-connect cord, as shown, is essential,
even if the system is not connected to a central station. Otherwise the 4285/4286 will not function and
an error signal (fast busy signal) will occur when accessing the system via the phone.
The house phone lines (gray and brown wires) must be wired to the phone module terminals; not to
the control terminals. Otherwise, an error signal (fast busy signal) will occur when trying to access
the system from an on-premises phone.
IMPORTANT NOTE FOR
EXISTING INSTALLATIONS:
EXISTING WIRES
CONNECTED TO THE
"HANDSET" TERMINALS ON
CONTROL MUST BE MOVED
FROM THERE TO TERMINALS
3 AND 4 ON THE 4285/4286.
LOUDER
VOLUME
(4286
ONLY)
UNUSED
CONNECTOR
WITH FLYING
LEADS

Long Range Radio Connections

Connect the data in/data out terminals and voltage input terminals of the Long Range Radio to
the control's keypad connection points.
Set the radio's address to "03" following the instructions provided with the radio.
Use compatible Long Range Radios (e.g., 7720PLUS, 7820, 7835C, or 7845C).
HANDSET
TERMINALS
21
ON CONTROL
CALLER ID
UNIT
4285/4286
V IP MODULE
KEYED
HEADER
YELLOW: TO DATA OUT (term. 7)
NO CONNECTION
RED:
TO AUX (+) (term. 5)
BLACK:
TO AUX. GROUND (–) (term.4)
GREEN: TO DATA IN (term. 6)
Figure 13. 4285/4286 Phone Module Wiring Connections
INCOMING
GROUND
TELCO LINE
22
23
24
25
TO EARTH GROUND (COLD WATER PIPE, ETC.)
INCOMING TELCO LINE
DIRECT
CONNECT
CORD
TIP
RJ31X
RING
JACK
CA38A
IN
PLUG
CANADA
* NOTE: IF THE TELEPHONE HAS BUILT-IN CALLER ID,
THE CALLER ID FUNCTION MAY NOT WORK .
TERMINAL ASSIGNMENTS
TO CONTROL
1 - TIP
PANEL
2 - RING
TERMINALS
3 - TIP
USED FOR
4 - RING
KEYPAD
5 - NO CONNECTION
CONNECTIONS
6 -
}
7 -
Mounting and Wiring the Control
PREMISES ANSWERING
MACHINE AND PHONES
ANSWERING
MACHINE
*
*
4285/4286
}
PHONE INPUT
}
PHONE OUTPUT
AUDIO OUT
4286 ONLY