Chauvet Gobo Shot User Manual

Gobo shot 50w irc

Advertisement

Quick Links

User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet Gobo Shot

  • Page 1 User Manual...
  • Page 2: Table Of Contents

    Wired Remote ............................14 Included Gobos ..........................15 Changing Gobos..........................15 5. Technical Information ....................16 Product Maintenance ........................16 6. Technical Specifications ....................17 Returns ............................18 Contact Us ............................18 Page 2 of 18 Gobo Shot™ 50W IRC User Manual Rev. 4...
  • Page 3: Before You Begin

    Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection. For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with CHAUVET® within 7 days of delivery. Text Convention Meaning 1—512...
  • Page 4: Product At A Glance

    This product is not intended for permanent installation. · Keep this User Manual for future use. If you sell the product to another user, be sure to give this document to the next owner. Page 4 of 18 Gobo Shot™ 50W IRC User Manual Rev. 4...
  • Page 5: Introduction

    Focus LED Display IRC Sensor Power In Fuse Holder DMX In DMX Out Power Out Wired Remote In Back Panel View Safety Loop Wired Remote Out Control Buttons Gobo Shot™ 50W IRC User Manual Rev. 4 Page 5 of 18...
  • Page 6: Dimensions

    Dimensions 12.6 in 320 mm 10.2 in 258 mm 12 in 306 mm Page 6 of 18 Gobo Shot™ 50W IRC User Manual Rev. 4...
  • Page 7: Setup

    3. S ETUP AC Power The Gobo Shot™ 50W IRC has an auto-ranging power supply and it can work with an input voltage range of 100~240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or...
  • Page 8: Power Linking

    Diagram Additional Products You can power link up to 9 Gobo Shot™ 50W IRC units on 120 VAC or up to 17 Gobo Shot™ 50W IRC units on 230 VAC. The power linking diagram shown above corresponds to the North American version of the product ONLY! If using the product in other markets, you must consult with the local CHAUVET®...
  • Page 9: Mounting

    Mounting Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. Orientation The Gobo Shot™ 50W IRC may be mounted in any position; however, make sure adequate ventilation is provided around the product. · Rigging Before deciding on a location, always make sure there is easy access to the product for maintenance and programming.
  • Page 10: Operation

    DMX mode uses. If you choose a starting address that is too high, you could restrict the access to some of the product’s channels. The Gobo Shot™ 50W IRC uses up to 4 DMX channels in its 4-channel DMX mode, which defines the highest configurable address to 509.
  • Page 11: Dmx Channel Modes, Assignments, And Values

    000 ó 063 Stop 064 ó 127 Rotation Gobo Rotation 128 ó 191 Stop 192 ó 255 Reverse rotation 000 ó 255 Gobo speed (slow to fast) Gobo Rotation Speed Gobo Shot™ 50W IRC User Manual Rev. 4 Page 11 of 18...
  • Page 12: Configuration (Standalone)

    Press <MENU> repeatedly until rESt shows on the display. Press <ENTER>. Load Factory To load the factory default settings in the Gobo Shot™ 50W IRC, do the following: Press <MENU> repeatedly until LoAd shows on the display. Defaults Press <ENTER>.
  • Page 13: Irc-6 (Infrared Remote Control)

    IRC-6 (Infrared The IRC-6 (infrared remote control) from CHAUVET® can be used to control one Gobo Shot™ 50W IRC. Set the product in Manual mode (nAn) to use the IRC-6. Remote Control) IRC-6 Operation Note: Make sure to point the IRC-6 directly at the receiver.
  • Page 14: Wired Remote

    To control the direction of the gobo’s rotation, flip the DIRECTION switch to either CCW (counter-clockwise) or CW (clockwise). · To control the power to the Gobo Shot™ 50W IRC, flip the POWER switch to either ON or OFF. The Wired Remote In/Out ports allow one Gobo Shot™ 50W IRC to remotely control the actions of another Gobo Shot™...
  • Page 15: Included Gobos

    Included Gobos Changing To change the gobos in the Gobo Shot™ 50W IRC, do the following: Turn off and disconnect the product from power. Gobos Place the product on a flat, level surface. Loosen the gobo door thumbscrew and pull open the hinged gobo door.
  • Page 16: Technical Information

    Always dry the external optics and glass/transparent surfaces carefully after cleaning them. Do not spin the cooling fan using compressed air because you could damage it. Page 16 of 18 Gobo Shot™ 50W IRC User Manual Rev. 4...
  • Page 17: Technical Specifications

    Cooling System 104 °F (40 °C) Fan-cooled I/O Connectors Connector Type Channel Range 3-pin XLR Sockets Product Name Item Code UPC Number Ordering Gobo Shot™ 50W IRC 03050718 781462210663 Gobo Shot™ 50W IRC User Manual Rev. 4 Page 17 of 18...
  • Page 18: Returns

    You must send the merchandise prepaid, in its original box, and with its original packing and accessories. CHAUVET® will not issue call tags. Clearly label the package with the RMA number. CHAUVET® will refuse any product returned without an RMA number.

Table of Contents