ALTERNATE ON/OFF SWITCH INSTALLATION

WIRING THE FIREpLACE
NOTICE: Electrical wiring must be installed by a licensed
electrician.
DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT
FOR EXTENDED TIME PERIODS. THIS WILL PREVENT AC-
CIDENTAL FIREPLACE OPERATION.
Installation of Alternate Surround panel ON/OFF Switch
An ON/OFF switch and wire assembly are provided. They are in-
cluded in the instruction packet.
Do not cut wire or insulation on metal edges.
NOTICE: Refer to surround panel installation section on page
15 for additional information on attachment.
Contemporary Surrounds
1.
Find the coiled low voltage wire assembly and ON/OFF switch
located in the instruction packet.
2.
Millivolt valve - Attach the flag terminal ends to the
"TH/TP" and "TH" terminals on the front terminal block
of the gas valve. See Figure 13.
"Ip" valve - Locate the two 5-1/2" long black wires connected
to the ON/OFF switch. Disconnect these two black wires at
the green and white wire connections. Attach the flag termi-
nals (the low voltage wire assembly found in the Instruction
Packet) to the green and white wire connections.
3. Run the low voltage alternate switch wires up the back of the
right or left surround panel. Then secure the wires with wire
clips provided. See Figure 11.
Insert ON/OFF switch into side panel then attach wire assem-
bly from valve terminals.
4. Remove the switch knockout on the side surround panel, then
install the ON/OFF switch.
5.
Connect the low voltage wires from the gas valve to the
ON/OFF switch.
6.
Attach the surround panel assembly to the insert. Place the
surround panel assembly against the face of the insert and
align the lower retaining tabs with the notches on the insert
sides. Lift the surround panel assembly slightly until the bot-
tom return flange (top panel) is positioned over the top flange
on the insert. This secures the surround panel assembly to
the insert without screws.
Page 14
CAUTION
Figure 11
Traditional Cast Iron Surrounds
1.
Find the coiled low voltage wire assembly and ON/OFF switch
located in the instruction packet.
2. Attach the flag terminal ends to the "TH/TP" and "TH" termi-
nals on the front terminal block of the gas valve. See Figure
13.
NOTICE:
For right side leg installation, reverse switch posi-
tion in bracket.
3. Run the low voltage alternate switch wires up the back of the
right or left cast surround leg. Then secure them with the wire
clips provided.
4. Install the switch bracket with screws as shown in Figure 12
to the back of the cast surround leg.
5.
Install ON/OFF switch, and connect low-voltage wires from
gas valve.
6.
Attach cast surround panel assembly to the insert. Place the
cast surround assembly against the face of the insert and
align the lower retaining tabs with the notches on the insert
sides. Lift the cast surround assembly slightly until the bottom
return flange (top panel) is positioned over the top flange on
the insert. This secures the cast surround assembly to the
insert without screws.
Figure 12