Empire Comfort Systems DVP42FP30N-4 Installation Instructions And Owner's Manual

Empire Comfort Systems DVP42FP30N-4 Installation Instructions And Owner's Manual

Direct vent, zero clearance gas fireplace heater millivolt standing pilot, direct ignition, intermittent pilot,remote rf
Table of Contents

Advertisement

: If not installed, operated and maintained
WARNING
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
mable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
— Installation and service must be per-
agency or the gas supplier.
WARNING
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
Note: Barrier required, but may be sold separately.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING
HOT GLASS
CAUSE BURNS.
DO NOT TOUCH
UNTIL COOLED.
NEVER
ALLOW CHILDREN
TO TOUCH GLASS.
DIRECT VENT, ZERO CLEARANCE
GAS FIREPLACE HEATER
MILLIVOLT STANDING PILOT
DVP(42,48)FP3(0,1,2,3)(N,P)-4
DVP(42,48)FP5(0,1,2,3)N-1
DVP(42,48)FP7(0,1,2,3)(N,P)-5
-
DVP(42,48)FP9(1,3)(N,P)-5
This appliance may be installed in
an aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by state or local
codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
WILL
GLASS
DIRECT IGNITION
INTERMITTENT PILOT
REMOTE RF
UL FILE NO. MH30033
GAS-FIRED
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems DVP42FP30N-4

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL GAS-FIRED INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. DIRECT VENT, ZERO CLEARANCE : If not installed, operated and maintained WARNING in accordance with the manufacturer’s instructions, GAS FIREPLACE HEATER this product could expose you to substances in fuel or from fuel combustion which can cause death or MILLIVOLT STANDING PILOT...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE IMPORTANT SAFETY INFORMATION ............................3 SAFETY INFORMATION FOR USERS OF LP GAS ........................4 REQUIREMENTS FOR MASSACHUSETTS ........................... 5 INTRODUCTION ....................................6 SPECIFICATIONS .................................... 7 VENT SYSTEM IDENTIFICATION ..............................8 SPECIAL VENT SYSTEMS ................................9 FIREPLACE DIMENSIONS ................................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED DANGER CAUTION NOTICE WARNING • If this appliance is installed directly on carpeting, tile or obstructed in any way.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP GAS with the members of your household. Someday when there and explosions. In its natural state, propane is odorless and may not be a minute to lose, everyone’s safety will depend colorless. You may not know all the following safety precautions on knowing exactly what to do.
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS permanently mounted to the exterior of the building at a the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print venting, including but not limited to decks and porches, the size no less than 1/2 inch in size, “GAS VENT DIRECTLY BELOW.
  • Page 6: Introduction

    (a) the installation or replacement of gas piping or (b) the connection, • Installation other than as instructed by Empire Comfort Systems, Inc. • Improper positioning of the logs, glass door or decorative rock.
  • Page 7: Specifications

    SPECIFICATIONS DVP42 DVP48 28,000 (Nat) 30,000 (Nat) Input Btu/hr Maximum 28,000 (LP) 30,000 (LP) 19,000 (Nat) 20,500 (Nat) Btu/hr Minimum (millivolt only) 22,000 (LP) 24,000 (LP) KWH (Maximum) (Minimum) NAT. #38 (.1015) P-203 - (DVP42FP(3,7,9)) #37 (.1040) P-213 - (DVP48FP(3,7,9)) 3.25 mm P-306 - (DVP42FP5) #34 P-270 - (DVP48FP5) Air Shutter Opening...
  • Page 8: Vent System Identification

    *Note: termination, see Figure 30. Special Venting Components (Simpson Duravent) See Empire Comfort Systems Retail Price List for Simpson Duravent part num- bers and pricing. Special DV Vent Kits Available from Empire Comfort Systems, Inc. dealers. Direct-Vent Fireplace Vent Kit - Vertical, Includes SD46DVA-VCH,...
  • Page 9: Special Vent Systems

    SPECIAL VENT SYSTEMS Simpson Duravent® GS 5" - 8" Simpson Duravent ® American Metal Products 5" - 8" Selkirk Direct-Temp® 5" - 8" Security Secure Vent® 5" - 8" Excel DV Venting 5” - 8” BDM 5” - 8” BDM 4” - 6 5/8” Empire Flexvent Kit DVVK-5F Empire Horizontal Round Termination Kit DVVK-4RE Duravent vents only.
  • Page 10: Clearances

    CLEARANCES Mantel Chart Clearance to Combustibles Back 0" (0 mm) Side 0" (0 mm) Floor 0" (0 mm) Top Stand-off 0" (0 mm) Top Framing Edge 3" (76 mm) Figure 5 Clearances Note A: See Figure 5 for maximum mantel depth. Note B: See Figure 5 for minimum height above unit.
  • Page 11: Locating Fireplace

    LOCATING FIREPLACE NOTICE: Island and Room Divider installation is possible as long When you install your Direct Vent Fireplace in Room divider or Flat as the horizontal portion of the vent system does not exceed 20 feet the appliance. CORNER CABINET INSTALLATION INSTALLATION...
  • Page 12: Gas Supply

    GAS SUPPLY The gas pipeline can be brought in through the right or left side of Installing a New Main Gas Cock the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. A manual main gas cock should be located in the vicinity of the unit. Recommended Gas Pipe Diameter contact your local authorized installer for installation or relocation.
  • Page 13: Installation

    INSTALLATION Framing and Finishing Choose unit location. See Figure 10B. NOTICE See Figure 10A. Figure 11 - Top Vent Vent Pipe Clearance Note: Maintain one inch of clearance around top vent pipe. See Figure 11. For rear vent, maintain a minimum 1” clearance to the bottom and sides of the vent, and 3”...
  • Page 14 INSTALLATION Flush Mount Mantel Installation Figure 13 to locate nailing sides. DVP42 DVP48 "A" 37 3/4" 37 3/4" "B" 43 3/8" 49 3/8" "C" 19 7/8" 19 7/8" Figure 14 Attention: base. WARNING: If a base or mantel is not used and the appliance is installed directly on carpeting, tile or other Figure 13 Attention:...
  • Page 15 INSTALLATION Flush Wall Installation Attention: Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Vent Runs certain components before the appliance is completely positioned and installed.
  • Page 16: Installation

    INSTALLATION REAR ONLY, STRAIGHT OUT THE BACK CORNER INSTALLATION TOP, 90° ELBOW TO HORIZONTAL OUT THE WALL "A" "B" MODEL 6"(152mm) 5 1/8"(130mm) to 6 /2"(165mm) DVP 42,48 Dim. DVP42 DVP48 9"(229mm) 8 1/8"(206mm) to 91/2"(241mm) DVP 42 45 3/8" 49 5/8"...
  • Page 17: Venting Fireplace - Top

    VENTING FIREPLACE - TOP Venting Graph (Dimensions in Feet) To Use the Vent Graph 1. Determine the height of the center of the horizontal vent the bottom of the graph. 3. Select the indicated dimension, and position the unit in EXAMPLE A: 6.5 feet.
  • Page 18 VENTING FIREPLACE - TOP Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12” (305mm) above grade level, a snorkel kit is recommended. The 7” (178mm) is measured from the center of the horizontal vent Ensure the sidewall venting clearances are observed.
  • Page 19: Venting Fireplace - Top

    VENTING FIREPLACE - TOP SEE FIGURE 22 FOR PERMISSIBLE “H” AND “V” DIMENISONS. Figure 27 Figure 26 MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE FIREPLACE HARD ELBOW DIMENSIONS SERIES "A"...
  • Page 20: Examples - Top Vent Run

    EXAMPLES - TOP VENT RUN Figure 30 Figure 29 Figure 31 Page 20 31455-10-1115...
  • Page 21: Venting Examples When Using Dva47 Adaptor

    VENTING EXAMPLES WHEN USING DVA47 ADAPTOR Vertically Off Top of Fireplace Only Simpson Duravent ® venting only. Figure 33 Figure 32 DVA47 ADAPTOR Example H1 = 2ft V1 = 20ft H = 2ft V = 20ft Figure 34 31455-10-1115 Page 21...
  • Page 22: Venting Fireplace - Rear

    VENTING FIREPLACE - REAR Venting Graph (Dimensions in Feet) To Use the Vent Graph 1. Determine the height of the center of the horizontal slanted graph line. line to the bottom of the graph. 3. Select the indicated dimension, and position the EXAMPLE A: EXAMPLE B: Special Note:...
  • Page 23: Examples - Rear Vent Run

    EXAMPLES - REAR VENT RUN Model Maximum Pipe Length H1 DVP42 24" DVP48 24" Figure 38 Figure 36 Model Maximum Pipe Length H1 DVP42 24" DVP48 24" Figure 39 Figure 37 31455-10-1115 Page 23...
  • Page 24: Rear Vent Conversion

    REAR VENT CONVERSION Figure 40 This completes the conversion for a rear vent application. Insert the insulation retainer bracket and insulation into the top WARNING: For top vented installations, the insulation and Page 24 31455-10-1115...
  • Page 25: Vent Clearances

    VENT CLEARANCES Figure 41 *Clearance above grade, veranda, porch, deck or balcony clearance to non-mechanical air supply inlet to building or [*12 inches (30cm) minimum] the combustion air inlet to any other appliance [*12 inches (30cm) minimum for appliances < 100,000 Btuh (30kW) 36 inches (90cm) minimum for appliances >...
  • Page 26: 8" Venting Framing And Finishing

    8" VENTING FRAMING AND FINISHING Installing Support Brackets A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance clearance on both sides and bottom of the 8 inch diameter pipe to Vertical runs of this vent systems must be supported every 4 feet members.
  • Page 27 8" VENTING FRAMING AND FINISHING (continued) Figure 46 Figure 44 See Horizontal Termination Page 31 and Vertical Termination Pages 32 and 33. Figure 45 31455-10-1115 Page 27...
  • Page 28 Installing Support Brackets A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to Vertical runs of this vent systems must be supported every 4 feet framing members.
  • Page 29 Figure 51 Figure 50 See Horizontal Termination Page 31 and Vertical Termination on Pages 32 and 33. 31455-10-1115 Page 29...
  • Page 30: Termination Clearances

    TERMINATION CLEARANCES Figure 52 Vertical Sidewall Installations Important! Important! Information on Various Venting Routes and Components Important See Figure 22, page 17. Page 30 31455-10-1115...
  • Page 31: Horizontal Termination

    HORIZONTAL TERMINATION NOTE: WARNING: Termination cap must be positioned so that Before attachment of the termination, run a bead of silicone sealant rated above 250°F on its outside edge too, so as to make a seal fasteners for use on stucco, brick, concrete or other types of siding.
  • Page 32: Vertical Termination

    VERTICAL TERMINATION Locate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this nail through this center point. Make the outline of the roof hole around this center point. NOTE: Size of the roof hole dimensions depend on the pitch of the roof.
  • Page 33 VERTICAL TERMINATION Installing the Vent System in a Chase Vertical Through the Roof Applications A chase is a vertical box-like structure built to enclose the gas Your Gas Fireplace has been approved for: appliance and/or it’s vent system. Vertical vent runs on the outside of a) Vertical installations up to 40 feet in height.
  • Page 34: Dvvk-4Re Vent Kit Installation Instructions

    DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS NOTICE: For top vent installation only: Use of a DVA47 adap- tor is required. CAUTION: Sharp edges, use protective gloves when installing. Tools Needed for Installation: Sheet metal snips 5/16” nut driver High temperature sealant or furnace cement rated for continuous use at 1,000 F minimum Measuring tape...
  • Page 35 DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS points to help in making a true cut. Do not crimp or enlarge tubes. 10. From outside: Push the 6 5/8” (168mm) diameter inlet tube/ mounting plate onto end of rigid venting system to correct position.
  • Page 36 DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS Follow correct option according to venting method. Connecting Directly to Fireplace Connecting to Rigid Vent System the unit (no rigid venting system is being used), then the gasket venting system (and not directly to the back of the unit), then do not use the gasket provided.
  • Page 37: Dvvk-5F Flex Vent Instructions

    DVVK-5F FLEX VENT INSTRUCTIONS The DVVK-5F FLEX VENT KIT high. The minimum combustible clearance from the horizontal nents: vent is 1” from sides and bottom, and 3” above the vent pipe. • (1) Horizontal Termination Cap See Figure 67. In most cases, after determining the length of the vent that is needed, it may be easier to install the flue and outer vent •...
  • Page 38: Propane/Lp Gas Conversion

    PROPANE/LP GAS CONVERSION Maxitrol Valve Conversion (Direct Ignition) Model AIR SHUTTER BURNER ORIFICE SETTINGS Opening "A" Figure 69 DVP42 Full Open DVP48 Full Open Figure 68 Page 38 31455-10-1115...
  • Page 39: Log Identification

    LOG IDENTIFICATION Part Number Front View Top View Description DVP42FP DVP48FP Log A R10349 R10357 Log B R10350 R10358 Log C R10351 R10359 Log D R10352 R10360 31455-10-1115 Page 39...
  • Page 40: Log Placement (4 Log Set)

    LOG PLACEMENT (4 LOG SET) Before you begin: If you are installing logs into the DVP42 or DVP48 Ember Placement Place decorative rock in front of grates and sides of main burner. After all logs are properly positioned, place small “dime” size Do not stack more than one layer of embers across the burner The positioning of logs is critical to safe and clean operation of this ports.
  • Page 41 31455-10-1115 Page 41...
  • Page 42 Page 42 31455-10-1115...
  • Page 43 31455-10-1115 Page 43...
  • Page 44 Page 44 31455-10-1115...
  • Page 45 Log assembly is completed. 31455-10-1115 Page 45...
  • Page 46: Millivolt System Operating Instructions

    MILLIVOLT SYSTEM OPERATING INSTRUCTIONS 750 Millivolt System The standing pilot (750 millivolt system) is a continuous burning When you ignite the pilot, the thermopile produces millivolts (electrical Initial Lighting Upon completing the gas line or turning the gas valve on after it has seconds to 1 minute time period you can release the gas control lines to purge themselves of this air.
  • Page 47 MILLIVOLT SYSTEM OPERATING INSTRUCTIONS STANDING PILOT OPERATING INSTRUCTIONS Installation of Remote Receiver Remote/Off/On Switch Attention: The velcro loop and hook are not necessary in this installation but can be used to secure remote receiver. Refer to remote control installation and operating instructions for more details on remote control.
  • Page 48: Millivolt System Standing Pilot Wiring Diagram

    MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM Figure 75 Page 48 31455-10-1115...
  • Page 49: Millivolt System Standing Pilot Lighting Instructions

    MILLIVOLT SYSTEM STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING causing property damage, personal injury or loss of life. department. Before lighting smell all around the appliance area for gas. Be C. Use only your hand to push in or turn the gas control knob. What To Do If You Smell Gas •...
  • Page 50: Millivolt System Standing Pilot Troubleshooting

    MILLIVOLT SYSTEM STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you diagnosis of problems and the corrective action to be taken. 1. Spark ignitor will not light pilot after repeated triggering of c.
  • Page 51: Direct Ignition Lighting Instructions

    DIRECT IGNITION LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING : IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY WARNING RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. BEFORE LIGHTING smell all around the appliance area for WHAT TO DO IF YOU SMELL GAS •...
  • Page 52: Direct Ignition Wiring Diagram

    DIRECT IGNITION WIRING DIAGRAM LED CODES Steady ON 2 Flashes 3 unsuccessful ignition trials 3 Flashes 4 Flashes Steady Flash Flame detected out of sequence Figure 76 OPTIONAL REMOTE CONTROL Electric (120 volt) Operated Remote Control (FREC) module (step 2). Connect female terminal from receiver onto 120 VAC hot terminal on control module.
  • Page 53: Initial Start Up Gas Line Purge

    INITIAL START UP GAS LINE PURGE NOTE: UNIT MUST BE PROPERLY GROUNDED FOR ELECTRONIC IGNITION TO FUNCTION. PURGE PROCEDURE 4 until ignition is achieved. If burner does not light after spark sequence has ended, use Turn burner off and install glass door frame assembly. 13 for fast reset function.
  • Page 54: Direct Ignition Propane/Lp Gas Conversion

    DIRECT IGNITION PROPANE/LP GAS CONVERSION The conversion shall be carried out in accordance with the 12. Install propane/LP main burner orifice marked #54 for requirements of the provincial authorities having jurisdiction DVP42FP or marked #51 for DVP48FP. and in accordance with the requirements of the CSA B149.2 installation code (Canada) and with the requirements of the National Fuel Gas Code Z223.1/NFPA 54 (United States).
  • Page 55: Ipi Electronic System Operating Instructions

    IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS 5.25 VDC ELECTRONIC CONTROL VALVE OPTIONAL REMOTE CONTROLS It is recommended that the remote receiver be placed either in a the pilot from a standing pilot mode to an intermittent pilot mode. • IPI Mode hind the left side surround panel, or in the control compartment •...
  • Page 56: Ipi Electronic System Wiring Diagram

    IPI ELECTRONIC SYSTEM WIRING DIAGRAM on the rating plate and may be installed in an aftermarket, prohibited by local codes. This appliance is not convertible for CAUTION removed, cracked or broken. Replacement of the liner(s) WARNING service or maintenance can cause property damage, personal Page 56 31455-10-1115...
  • Page 57: Intermittent Pilot Lighting Instructions

    INTERMITTENT PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: causing property damage, personal injury or loss of life. C. Use only the remote control or manual remote receiver vice technician. Force or attempted repair may result in a BEFORE LIGHTING smell all around the appliance area for WHAT TO DO IF YOU SMELL GAS appliance and to replace any part of the control system and...
  • Page 58: Intermittent Pilot Control System Troubleshooting

    INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING Brief Description of the Components ual modulation of the gas outlet pressure to the appliance burner. Gas and can be converted by use of an OEM supplied conversion kit. The Digital Fireplace Control (DFC) is an automatic gas ignition system based on a single microcontroller core.
  • Page 59 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING If the DFC giving signal lock out: Verify the electrical connections’ integrity and The board should be unlocked to make sure they are in accordance with the relevant reinitiate a pilot flame ignition (for Is the DFC board in system wiring diagram.
  • Page 60 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING Page 60 31455-10-1115...
  • Page 61: Rf Operating Instructions

    RF OPERATING INSTRUCTIONS RF VALVE OPERATION (AF-4040 Electronic Gas Valve system only) Please refer to the separate instructions for detailed operation and programming of the Multi-function Remote Control. The AF-4040 Electronic Gas Control Valve features a Remote The Control Module must be programmed to the Remote Control. To program, located the learn button on the left side of the pane or natural gas (pre-set at the factory).
  • Page 62: Rf Maintenance Instructions

    RF MAINTENANCE INSTRUCTIONS MAINTENANCE TROUBLESHOOTING Maintenance frequency must be determined individually for each IMPORTANT: All service and trouble-shooting procedures should application. Some considerations are: • Cycling frequency. Appliances that may cycle 20,000 times nected to the Control Module “S” and “I” terminals. annually should be checked monthly.
  • Page 63: Rf Wiring Diagram

    RF WIRING DIAGRAM Note: remote control system. Figure 79 31455-10-1115 Page 63...
  • Page 64: Rf Standing Pilot Lighting Instructions

    RF STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING : IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR WARNING EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with C.
  • Page 65: Maintenance And Service

    MAINTENANCE AND SERVICE Please Note WARNING: It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start Care must be taken to avoid breakage of the glass. up or cool down cycle. Similar noises are found with your Under no circumstances should this appliance be operated furnace heat exchanger or car engine.
  • Page 66: Dvp42Fp(3,5,7,9) Parts List

    DVP42FP(3,5,7,9) PARTS LIST Part Number Index No. Description DVP42FP3 DVP42FP5 DVP42FP7 DVP42FP9 R7654 R7654 R7654 R7654 Insulation, Flue 17426 17426 17426 17426 Retainer, 5” Flue R7567 R7567 R7567 R7567 Vent Adapter R7573 R7573 R7573 R7573 Inlet Vent Gasket 17363 17363 17363 17363 Flue Outlet Assembly...
  • Page 67 DVP42FP(3,5,7,9) PARTS LIST Part Number Index No. Description DVP42FP3 DVP42FP5 DVP42FP7 DVP42FP9 R3436 R2522 R7615 Cord Set R8144 Wire Harness (DI) R11123 Wire Harness (IP) 18880 18858 FBB4 FBB4 FBB4 R7731 R7831 R10352 R10352 R10352 R10352 R10350 R10350 R10350 R10350 Log, Front Left R10351 R10351...
  • Page 68: Dvp48Fp(3,5,7,9) Parts List

    DVP48FP(3,5,7,9) PARTS LIST Part Number Index Description DVP48FP3 DVP48FP5 DVP48FP7 DVP48FP9 R7654 R7654 R7654 R7654 Insulation, Flue 17426 17426 17426 17426 Retainer, 5” Flue R7567 R7567 R7567 R7567 Vent Adapter R7573 R7573 R7573 R7573 Vent Gasket 17363 17363 17363 17363 Flue Outlet Assembly M170 M170...
  • Page 69: Dvp48Fp(3,5,7,9) Parts List

    DVP48FP(3,5,7,9) PARTS LIST Index Part Number Description DVP48FP3 DVP48FP5 DVP48FP7 DVP48FP9 R8144 Wire Harnes (DI) R11123 Wire Harness (IP) 18880 18858 FBB4 FBB4 FBB4 R7731 R7831 R10360 R10360 R10360 R10360 R10358 R10358 R10358 R10358 Log, Front Left R10359 R10359 R10359 R10359 Log, Front Right R10357...
  • Page 70: Parts View

    PARTS VIEW Page 70 31455-10-1115...
  • Page 71: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. Dey Distributing Victor Division of F. W. Webb Company...
  • Page 72: Fbb4 Optional Variable Speed Blower Installation

    FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION Attention: Install blower assembly before connecting gas inlet supply line Note: 6. Position speed control box to the right of gas valve. Attach box in place. 4. Refer to page 68, "Junction Box Wiring Installation Instructions" Attention: If installed, do not damage gas inlet supply line necessary, remove gas inlet supply line.
  • Page 73: Fbb4 Optional Variable Speed Blower Installation

    FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION R7731 BLOWER MOTOR 31920 SWITCH ASSEMBLY R4192 SPEED CONTROL KNOB R4186 SPEED CONTROL 31455-10-1115 Page 73...
  • Page 74: Junction Box Wiring Installation Instructions

    JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LO- CAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LAT- EST EDITION).
  • Page 75: Accessories

    ACCESSORIES Accessory Description Model Number Fan Kit Variable Speed FBB4 assembly.) Simulated Brick Liners DVP3DH(DVP42) DVP4DH(DVP48) masonry. HERRINGBONE Simulated Brick Liners DVP3DA(DVP42) DVP4DA(DVP48) masonry. AGED BRICK DECORATIVE ACCESSORIES Decorative Louver Leaf Decorative Louver Mission Decorative Louver Arch Decorative Door Plain Rectangle Decorative Frame Rectangle STD Louvers 45 Degree Outside Frame Kits...
  • Page 76: Quick Reference Guide

    EMPIRE Empire Comfort Systems EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems The Tahoe Direct Vent Zero Clearance Gas Fireplace Heater GAS-FIRED MILLIVOLT STANDING PILOT: DVP(42,48)FP3(0,1,2,3)(N,P)-4 DIRECT IGNITION PILOT: DVP(42,48)FP5(0,1,2,3)-1 INTERMITTENT PILOT: DVP(42,48)FP7(0,1,2,3)(N,P)-5 REMOTE RF: DVP(42,48)FP9(1,3)(N,P)-5 Fireplace requires one of the following fronts:...
  • Page 77: Firebox Dimensions

    Empire Comfort Systems EMPIRE EMPIRE 918 Freeburg Avenue Belleville, Illinois 62220-2623 Comfort Systems The Tahoe Direct Vent Zero Clearance Gas Fireplace Heater GAS-FIRED MILLIVOLT STANDING PILOT: DVP(42,48)FP3(0,1,2,3)(N,P)-4 DIRECT IGNITION PILOT: DVP(42,48)FP5(0,1,2,3)-1 INTERMITTENT PILOT: DVP(42,48)FP7(0,1,2,3)(N,P)-5 REMOTE RF: DVP(42,48)FP9(1,3)(N,P)-5 Fireplace requires one of the following fronts:...
  • Page 78: Fireplace Service History

    FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes Page 78 31455-10-1115...
  • Page 79: Warranty

    WARRANTY Limited Lifetime Parts Warranty – Combustion Chamber, Heat Exchanger, and Factory-Installed Glass Limited Three-Year Parts Warranty – All Other Components (Except Remote Controls, Thermostats, Accessories and Replacement Parts) repair or replace at Empire’s option.. Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts Duties Of The Owner pliance.
  • Page 80 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems...

Table of Contents