Ambient Temperature; Temperature Gradient; Humidity; Altitude - Seagate ST4000VX000 Product Manual

Surveillance hdd
Hide thumbs Also See for ST4000VX000:
Table of Contents

Advertisement

www.seagate.com

2.9.2 Ambient Temperature

Operating
0° to 70°C
Non-operating
–40° to 70°C

2.9.3 Temperature gradient

Operating
20°C per hour (68°F per hour max), without condensation
Non-operating
30°C per hour (86°F per hour max)

2.9.4 Humidity

2.9.4.1
Relative humidity
Operating
5% to 90% non-condensing (30% per hour max)
Nonoperating
5% to 95% non-condensing (30% per hour max)
2.9.4.2
Wet bulb temperature
Operating
37.7°C (99.9°F max)
Non-operating
40°C (104°F max)

2.9.5 Altitude

Operating
–304m to 3048m (–1000 ft. to 10,000 ft.)
Non-operating
–304m to 12,192m (–1000 ft. to 40,000+ ft.)

2.9.6 Shock

All shock specifications assume that the drive is mounted securely with the input shock applied at the drive
mounting screws. Shock may be applied in the X, Y or Z axis.
2.9.6.1
Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum
operating shock of 80 Gs based on half-sine shock pulses of 2ms during read operations. Shocks should not be
repeated more than 2 times per second.
2.9.6.2
Non-operating shock
3TB and 4TB
The non-operating shock level that the drive can experience without incurring physical damage or degradation in
performance when subsequently put into operation is 300 Gs based on a non-repetitive half-sine shock pulse of
2ms duration.
Seagate Surveillance HDD Product Manual, Rev. A
Drive Specifications
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

St3000vx002

Table of Contents