D-Link xStack Reference Manual page 1084

Dgs-3120 series layer 3 managed gigabit switch
Hide thumbs Also See for xStack:
Table of Contents

Advertisement

®
xStack
DGS-3120 Series Layer 3 Managed Gigabit Switch CLI Reference Guide
Multicast storm
occurrence
Multicast storm cleared
Port shut down due to a
packet storm
Loop Back
Port loop occurred
Dection
Port loop detection
restarted after interval
time
Port with VID loop
occurred
Port with VID Loop
detection restarted after
interval time
The number of VLANs
that loop back has
occured hit the specified
number.
Gratuituios ARP
Gratuituios ARP detected
duplicate IP.
DHCP
Detect untrusted DHCP
server IP address
BPDU Protection
BPDU attack happened
BPDU attack
automatically recover
BPDU attack manually
recover
MONITOR
Temperature exceeds
confidence level
Temperature recovers to
normal.
CFM
Cross-connect is detected
Error CFM CCM packet is
detected
Can not receive remote
MEP's CCM packet
Remote MEP's MAC
reports an error status
Remote MEP detects
CFM defects
Port <[unitID:]portNum>
Multicast storm is occurring
Port <[unitID:]portNum>
Multicast storm has cleared
Port <[unitID:]portNum> is
currently shut down due to a
packet storm
Port <[unitID:]portNum> LBD
loop occurred. Port blocked
Port <[unitID:]portNum> LBD
port recovered. Loop detection
restarted
Port <[unitID:]portNum> VID
<vlanID> LBD loop occurred.
Packet discard begun
Port <[unitID:]portNum> VID
<vlanID> LBD recovered. Loop
detection restarted
Loop VLAN number overflow
Conflict IP was detected with this
device (IP: <ipaddr>, MAC:
<macaddr>, Port
<[unitID:]portNum>, Interface:
<ipif_name>).
Detected untrusted DHCP
server(IP: <ipaddr>, Port:
<[unitID:]portNum>)
Port <[UnitID:]portNum> enter
BPDU under attacking state
(mode: drop / block / shutdown)
Port <[UnitID:]portNum> recover
from BPDU under attacking state
automatically
Port <[UnitID:]portNum> recover
from BPDU under attacking state
manually
[Uint <unitID>] Temperature
Sensor <sensorID> enter alarm
state. (current temperature:
<temperature>)
[Uint <unitID>] Temperature
Sensor <sensorID> recovers to
normal state. (current
temperature: <temperature>)
CFM cross-connect.
VLAN:<vlanid>, Local(MD
Level:<mdlevel>, Port
<[unitID:]portNum>,
Direction:<mepdirection>)
Remote(MEPID:<mepid>,
MAC:<macaddr>)
CFM error ccm. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>)
Remote(MEPID:<mepid>,
MAC:<macaddr>)
CFM remote down. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>)
CFM remote MAC error. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>)
CFM remote detects a defect.
MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
1079
Warning
Informational
Warning
Critical
Informational
Critical
Informational
Informational
Warning
Informational
DHCP Server
Screening
Informational
Informational
Informational
Warning
Informational
Critical
Warning
Warning
Warning
Informational

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xstack dgs-3120-24tc

Table of Contents