1

Safety considerations

1.1

Key to symbols

Warnings
Warnings in this document are identified by a warning
triangle printed against a grey background.
Keywords at the start of a warning indicate the type and
seriousness of the ensuing risk if measures to prevent
the risk are not taken.
The following keywords are defined and can be used in this document:
• NOTE indicates a situation that could result in damage to property or
equipment.
• CAUTION indicates a situation that could result in minor to medium
personal injury.
• WARNING indicates a situation that could result in severe personal
injury or death.
• DANGER indicates a situation that will result in severe injury or death.
Important information
This symbol indicates important information where
there is no risk of personal injury or property damage.
Additional symbols
Symbol
Explanation
Step in an action sequence
Cross-reference to another part of the document
List entry
List entry (second level)
Table 1
1.2

Safety instructions

Observe these instructions for your safety.
The burner and control must be correctly installed and adjusted to
ensure safe and economical operation of the gas boiler.
Read this installation and maintenance manual carefully and note the
details on the boiler nameplate before placing the boiler in operation.
Risk of fatal injury from explosion of flammable gases
If you smell gas there is a danger of explosion.
▶ Never work on gas lines unless you are licensed for this type of work.
▶ Make sure that a qualified company installs the boiler, connects gas
and ventplaces the boiler in operation, connects the electrical power,
and maintains and repairs the boiler.
▶ No open flame! No smoking! Do not use lighters
▶ Prevent spark formation. Do not operate electrical switches,
including telephones, plugs or door bells.
▶ Close main gas valve.
▶ Open doors and windows.
▶ Warn other occupants of the building, but do not use door bells.
▶ Call gas company from outside the building.
▶ If gas can be heard escaping, leave the building immediately, prevent
other people from entering, notify police and fire departments from
outside the building.
Logano GC 124 II – 6 720 804 440 (2012/11)
Risk to life from electrical shock.
▶ Disconnect the power supply to the boiler heating system before
conducting any work on it, e.g. turn off the heating system emergency
switch outside the boiler room.
▶ It is not sufficient just to turn off the control.
▶ Do not carry out electrical work unless you are qualified for this type
of work.
▶ Before disconnect electrical power completely and pad lock to
prevent accidental reconnection.
▶ Observe the local installation regulations.
Risk of fatal injury from flue gas poisoning
Insufficient ventilation or combustion air availability may cause
dangerous flue gas leaks or formation.
▶ Make sure that inlets and outlets are not reduced in size or closed.
▶ If faults are not corrected immediately, the boiler must not be
operated until all faults have been corrected.
▶ Inform the system operator and/or owner of the fault and the danger
in writing.Elektroanschluss nur durch eine Elektrofachkraft ausführen
lassen.
When working on the flue gas venting equipment or vent damper leakage
of flue gases may endanger the lives of people.
▶ Carefully observe proper operation of the vent damper. Do not start
up the boiler unless the vent damper is operating properly.
▶ Use only original parts when replacing parts.
▶ When replacing the vent damper, install the new one in the specified
position.
Risk to life by poisoning by spillage of flue gases
▶ If the blocked vent switch trips frequently the fault must be corrected
and proper operation of the blocked vent switch test must be
conducted.
Risk to life by poisoning by leakage of flue gases
▶ Make sure that the boiler is not equipped with a thermally controlled
flue gas vent damper after the open draft hood.
Risk of fatal injury from neglecting your own safety in case of
emergency, such as with a fire
▶ Never put yourself at risk. Your own safety must always take priority.
Fire danger due to flammable materials or liquids
▶ Make sure that there are no flammable materials or liquids in the
immediate vicinity of the boiler.
▶ Maintain a minimum distance of 15 inches from the boiler.
Installation and maintenance
▶ Observe all current standards and guidelines applicable to the
installation and operation of the boiler heating system as applicable in
your state or local jurisdiction.
▶ Clean and service the boiler system once a year. Check that the
complete heating system operates correctly.
▶ Immediately correct all faults to prevent system damage.
▶ Only use original Buderus spare parts. Losses caused by the use of
parts not supplied by Buderus are excluded from the Buderus
warranty.