Sharp AL-1661CS Service Manual page 88

Digital multifunctional system
Hide thumbs Also See for AL-1661CS:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
26
03
Second cassette setting
(2ND TRAY)
04
Main unit duplex setting
(DPLX)
06
Destination setting
(DESTINATION)
07
Machine conditions check
(CPM)
20
Rear edge void setting (END
EDGE)
30
CE mark support control ON/
OFF (CE MARK)
[Function]
When this test command is executed, the current set second cassette is displayed. Enter the code
number corresponding to the desired second cassette and press [ENTER/START] key to save the
setting.
Code number
0
Second cassette NO
1
Second cassette YES
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set duplex is displayed. Enter the code number cor-
responding to the desired duplex and press [ENTER/START] key to save the setting.
Code number
0
Duplex NO
1
Duplex YES
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set destination is displayed. Enter the code number
corresponding to the desired destination and press [ENTER/START] key to save the setting.
Code number
0
1
2
3
For Japan AB series, there is no schedule for production.
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current machine setting is displayed.
CPM
10 CPM
12 CPM
13 CPM
14 CPM
15 CPM
16 CPM
[Operation]
1) The machine setting is displayed.
26-07 CPM
10 CPM
[Function]
When this test command is executed, the current set rear edge void is displayed. Enter the code num-
ber corresponding to the desired rear edge void and press [ENTER/START] key to save the setting.
Code number
0
Rear edge void NO
1
Rear edge void YES
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set CE mark support control is displayed. Enter the
code number corresponding to the desired CE mark support control and press [ENTER/START] key
to save the setting.
Code number
0
CE mark support control OFF
1
CE mark support control ON
[Operation]
The operation is similar to test command 21-01.
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 12
Details of function/operation
Second cassette
Display item
Duplex
Display item
OFF
ON
Destination
Inch series
EX Japan AB series
Japan AB series
China (EX Japan AB series + China paper support)
Coy quantity
Remark
10
12
13
14
15
16
Setting
Display item
OFF
ON
Setting
OFF
ON
Display item
INCH
AB
CHINA
Remark
Default
Display item
Remark
OFF
Default (100V series)
ON

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents