8
01
Developing bias output
(DVLP BIAS SET.)
02
Main charger output (Grid
HIGH) (MHV(H) SET.)
03
Main charger output (Grid
LOW) (MHV(L) SET.)
06
Transfer charger output
(THV SET.)
9
01
Duplex motor normal
rotation check (DPLX ROT.)
02
Duplex motor reverse
rotation check (DPLX
ROT.REV.)
04
Duplex motor rotating speed
adjustment (DPLX
ROT.SPEED)
[Function]
When [ENTER/START] key is pressed, the developing bias signal is turned ON for 30sec.
When, however, an actual output value is measured, use test command 25-01.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
1) Initial display
08-01 DVLP BIAS SET.
EXECUTING...
[Function]
When [ENTER/START] key is pressed, the main charger is outputted for 30sec in the grid voltage
HIGH move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
1) Initial display
08-02 MHV(H) SET.
EXECUTING...
[Function]
When [ENTER/START] key is pressed, the main charger is outputted for 30sec in the grid voltage
LOW move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
1) Initial display
08-03 MHV(L) SET.
EXECUTING...
[Function]
When [ENTER/START] key is pressed, the transfer charger is outputted for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
1) Initial display
08-03 THV SET.
EXECUTING...
[Function]
Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direction) for
30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
1) Initial display
09-01 DPLX ROT.
EXECUTING...
[Function]
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
1) Initial display
09-02 DPLX ROT.REV.
EXECUTING...
[Function]
When this Test Command is executed, the currently set value is displayed.
Enter the adjustment value with [10KEY] and press [START] key. The entered value is stored and the
machine goes into the sub code entry standby mode. The greater the set value is, the higher the
speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 6)
1) Initial display
09-04 DPLX ROT.SPEED
6( 1-13)
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 7
Details of function/operation
2)
/10KEY]
09-04 DPLX ROT.SPEED
7( 1-13)
2) [ /10KEY]
09-04 DPLX ROT.SPEED
5( 1-13)
3) [ENTER/START]
09-04 DPLX ROT.SPEED
7( 1-13)