Sharp AL-1661CS Service Manual page 141

Digital multifunctional system
Hide thumbs Also See for AL-1661CS:
Table of Contents

Advertisement

SW63 No.1, No.2 CI receive number to shift to non-V.34
communication
Used to set CI receive number to shift to non-V.34 communication.
Default: 1 0 (2 times)
SW63 No.3–No.5 CI send number to shift to non-V.34
communication
Used to set CI send number to shift to non-V.34 communication.
Setting is made in binary input.
Default: 2
SW63 No.6–No.8 Inhibited to use
SW64 No.1–No.8 Inhibited to use
SW65 No.1–No.8 Inhibited to use
SW66 No.1–No.8 Inhibited to use
SW67 No.1–No.4 Make time (10PPS) setup
Used to set make time in dialing in 10PPS.
Setting is made in binary input in the increment of 1ms.
Default: 40ms
SW67 No.5–No.8 Inhibited to use
SW68 No.1, No.2 Line open delay time in dial test
Used to set time interval between end of dialing and opening the line.
Valid only in dial test of simulation.
Default: 0 0 (2sec)
SW68 No.3, No.4 Inhibited to use
SW68 No.5–No.8 T1 timer setup
Used to set time for connection of the line when the remote machine
does not respond in FAX communication.
The time of ITU-T standard is 35 ± 5sec.
Setting is made in binary input in the increment of 5sec.
Default: 40sec
SW69 No.1–No.8 Inhibited to use
SW70 No.1–No.3 Inhibited to use
SW70 No.4 Reception waiting time between frames
Used to set reception wait time between frames.
Default: 0 (3.4sec)
SW70 No.5, No.6 Preamble send time of 300bps
Used to set preamble send time of 300bps.
Default: 0 1 (1.0sec)
SW70 No.7, No.8 RCP send times
Used to set number of times of RCP frame send.
Default: 0 0 (3 times)
SW71 No.1–No.8 Inhibited to use
SW72 No.1 EYE-Q check
Used to set TCF check in TCF reception.
When set to 1, check is made only with EYE-Q value (EQM value).
Therefore, TCF check is loosely made.
When set to 0, check is made with received data and EYE-Q value
(EQM value).
Default: 0 (0 reception & EYE-Q check)
SW72 No.2 ERR frame reception operation
Used to set operations when an image with an error frame is received.
Default: 0 (Not continue process. (Error))
SW72 No.3, No.4 Waiting time for CED/ANSam send start
Used to set waiting time from when the line is connected and the
machine enters FAX receive state to when CED/ANSam signal is send
to the line.
Default: 0 0 (2.25sec)
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 65
SW72 No.5 RTC EOL send times
Used to set number of times of RTC EOL send.
Default: 1 (6 times)
SW72 No.6 Inhibited to use
SW72 No.7, No.8 CNG send start
Used to set CNG send time.
Default: 0 0 (0.5sec)
SW73 No.1, No.2 Minimum flags between frames
Used to set minimum flag number between frames.
Default: 0 0 (2-flag)
SW73 No.3, No.4 Phase C head dummy data send time
Used to set phase C head dummy data send time.
Default: 0 0 (0.2sec)
SW73 No.5, No.6 Inhibited to use
SW73 No.7, No.8 Flag-adrs timer setup (V.21-FSK)
Used to set timer between Flag-adrs in FSK signal receive in commu-
nication other than V.34 mode.
FSK signal receive in V.34 mode does not conform to this soft switch.
Default: 0 0 (6sec)
SW74 No.1–No.4 Print effective image area sub scan lead
edge void
Used to set print image area void.
The void amount on the lead edge in the sub scan direction can be
adjusted. When the set value is increased, the void amount on the lead
edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 32 lines
SW74 No.5–No.8 Inhibited to use
SW75 No.1, No.2 Inhibited to use
SW75 No.3, No.4 Communication end sound (Buzzer
sound length) setting
Used to set the length of communication end buzzer sound in commu-
nication.
Default: 0 0 (3sec)
SW75 No.5–No.8 Print effective image area main scan
void
Used to set void amount in print image area.
The void amount in the main scan direction can be adjusted. When the
set value is increased, the margins on the right and the left are
increased.
Setting is made in binary input in the increment of 16 dots.
Default: 48 dots
SW76 No.1–No.8 Scan magnification ratio adjustment
(SPF main scan)
Used to set main scan magnification ratio in SPF scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW77 No.1–No.8 Scan magnification ratio adjustment
(SPF sub scan)
Used to set sub scan magnification ratio in SPF scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW78 No.1–No.8 Print magnification ration adjustment
(main scan)
Used to set main scan magnification ratio in print.
Setting is made in binary input in the increment of 0.1%.
Default: 0%