Test Pattern Printing: Sp2-902; Test Pattern Table (Sp2-902-2: Ipu Test Print) - Ricoh A-C4 Service Manual

Machine code: b195/b198/b264/b265
Table of Contents

Advertisement

20 June 2005

5.2.4 TEST PATTERN PRINTING: SP2-902

NOTE: Always print a test pattern to confirm correct operation of the machine.
1. Enter the SP mode and select SP2-902.
2. Press  or .
 IPU Test Print
 Test Pattern
3. Enter the number for the test pattern that you want to print and press . (See
the tables below.)
4. When you are prompted to confirm your selection, press Yes. This selects the
test pattern for printing.
5. Press Copy Window to open the copy window and then select the settings for
the test print (paper size, etc.)
6. Press Start  twice. (Ignore the "Place Original" messages) to start the test
print.
7. Press SP Mode (highlighted) to return to the SP mode display.

Test Pattern Table (SP2-902-2: IPU Test Print)

No.
Test Pattern
0
None
1
Vertical Line (1-dot)
2
Horizontal Line (1-dot)
3
Vertical Line (2-dot)
4
Horizontal Line (2-dot)
5
Alternating Dot Pattern
6
Grid Pattern (1-dot)
7
Vertical Strips
SERVICE PROGRAM MODE TABLES
No.
Test Pattern
8
Grayscale (Horizontal)
9
Grayscale (Vertical)
10
Cross Pattern
11
Cross Shape
12
Argyle Pattern
13
Cross Pattern (256)
14
Cross Pattern (64)
5-117