7. DRAWER
[OUTLINE]
• Standard equipment
: Yes (1)
• Max. number of drawers : 1
• The drawer consists of
:
(1) Drawer box (outer case) and drawer
(2) Money case
(3) Coin case
(4) Lock (attached to the drawer)
[SPECIFICATION]
1)
DRAWER BOX AND DRAWER
Material
Plastic
Bell
-
Release lever
Standard equipment: situated at the bottom
Drawer open sensor
-
2)
MONEY CASE
Separation from the drawer
Separation of the bill compartments from the coin
compartments
Bill separator
Number of compartments
Layout:
4B/5C (u)
3) LOCK (LOCK KEY : LKGIM7331BHZZ)
• Location of the lock: Front
• Method of locking and unlocking:
• To lock, insert the drawer lock key into the lock and turn it 90 degrees
counter clockwise. To unlock, insert the drawer lock key and turn it 90
degrees clockwise.
• Key No: SK1-1
8. BATTERY
1) MEMORY BACK UP BATTERY
For memory back up, the dry battery ULM-3 (3 ) are needed.
1. Memory holding time:
Approx. 1 year after New dry batteries are installed.
2. Battery exchange method:
When the low battery symbol "L" lights up, replace the batteries (3
AA) replaced by the following method;
1) Power on the ECR.
2) Mode switch turn to "REG" mode.
3) Remove the OLD dry batteries (3 pieces).
4) The nobattery symbol "L" light up.
5) Insert the NEW dry batteries (3 pieces).
6) Confirm the low battery symbol "L" and nobattery symbol "L" is
off.
2) LOW BATTERY
Low battery indication will appear on the left side of display when the
battery voltage is low.
CASE 1: When sitting idle or after completion of transaction.The
CASE 2: Low battery indication will not appear during key operations,
[Display sample]
" 0.00 " : Battery is OK.
"L 0.00" : Low battery (You have to change the batteries.)
After finalization
"F 12.34": Battery is OK.
"L 12.34": Low battery ("L" indicate instead of "F".)
3) NO BATTERY
If the user forgets to replace the battery and the battery voltage falls
below a certain level, or if a power failure occurs with no batteries
installed, the memory contents cannot be retained. The CPU judges it
as no battery and performs the master reset. In this case, all the set-
Disallowed
tings and registrations are cleared. If, however, the power is continu-
ously supplied to the AC cord, the memory contents are retained.
Allowed
-
Low battery : Batteries are installed, but the voltage is low. Memory
-
4B/5C (U)
No battery : Batteries are not installed or the voltage is extremely low.
3B/5C (V)
Low battery & No battery indication will appear at the most left position
of display when the battery voltage is low.
CASE 1: When any numeric entry & item entry is not done or just after
CASE 2: When numeric entry or item entry is done.
3B/6C (v)
[Display sample]
After finalization
XE-A102 SPECIFICATIONS
– 3 –
machine can indicate the low battery condition (Always)
but will appear after power up of the cash register.
back up can be done.
The master reset is executed when a power failure
occurs, when the batteries are not properly changed.
finalization. The machine can indicate the battery condition.
(Always)
Battery condition does not appear.
Except when power is restored after power failure, the
Low battery & No battery indication will appear on the
display only when the battery voltage is low.
And the indication will disappear after any key entry.
" 0.00" : Battery is OK.
"L 0.00" : Low battery
"L 0.00" : No battery
"F 12.34": Battery is OK.
"L 12.34": Low battery ("L" indicate instead of "F".)
"
12.34": No battery ("L" indicate instead of "F".)
L
L
L