Indoor Unit Installation Drawings - Daikin H-Series Engineering Data

H-series cooling only / heat pump split-system room air conditioners
Hide thumbs Also See for H-Series:
Table of Contents

Advertisement

EDUS04-924A
A Mounting plate
B
Mounting plate fixing
screws 3/16" × 1"L (M4 × 25L) (9)
Front panel
1-15/16" (50mm) or
more from walls
(on both sides)
3/16" × 5/8"L
(M4 × 16L)
C Titanium Apatite Photocatalytic
Air-Purifying Filter (3)
Titanium Apatite Photocatalytic
Air-Purifying Filter
Filter frame
Tab
Intelligent-eye Sensor
CAUTION
1) Do not hit or forcefully push the intelligent- eye sensor . . This can lead to damage and malfunction.
2) Do not place large objects near the sensor.
sensor's detection area.
Room Air Conditioners H-Series

Indoor Unit Installation Drawings

The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
3/16" × 5/8"L
3/16" × 5/8"L
(M4 × 16L)
(M4 × 16L)
Screw cover
M
Air filters
Air filter
How to attach the indoor unit.
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit.
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
release, remove the front grille.
1-3/16" (30mm) or more
from ceiling
Intelligent-eye sensor
Front grille fixture
How to remove front grille fixture
1) Insert the tool into the groove of the
front grille fixture.
Front grille fixture
Bottom of indoor unit
2) Turn the tool 90 in the direction of
the arrow.
3) Take out the front grille fixture.
D
F
Fixing screws for
remote controller holder
1/8" × 13/16"L
(M3 × 20L) (2)
Keep heating units or humidifiers outside the
Installation Manual
A Mounting
Clip
Bottom frame
Mark (rear side)
Front grille
Cut thermal insulation
pipe to an appropriate
Caulk
length and wrap it with
pipe hole
tape, making sure that no
gap
gap is left in the insulation
with putty.
pipe's cut line.
Wrap the insulation pipe with
the finishing tape from bottom
to top.
Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.
Before screwing the remote
Wireless
controller holder to the wall,
remote
make sure that control
controller
signals are properly
received by indoor unit.
E
Remote
controller holder
plate
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents