Troubleshooting System Cooling Problems; Troubleshooting A Fan - Dell PowerEdge C2100 Hardware Owner's Manual

Servers
Hide thumbs Also See for PowerEdge C2100:
Table of Contents

Advertisement

Troubleshooting System Cooling Problems

CAUTION:
You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.
Ensure that none of the following conditions exist:
System cover, cooling shroud, drive blank, power supply blank, or front or
back filler panel is removed.
Ambient temperature is too high.
External airflow is obstructed.
Cables inside the system obstruct airflow.
An individual cooling fan is removed or has failed. See "Troubleshooting a
Fan" on page 116.

Troubleshooting a Fan

CAUTION:
You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.
1 Locate the faulty fan indicated by the LED panel.
2 Turn off the system and all attached peripherals.
3 Open the system. See "Opening the System" on page 58.
4 Reseat the fan's power cable.
5 Restart the system.
If the fan functions properly, close the system. See "Closing the System" on
page 59.
116
Troubleshooting Your System
Many repairs may only be done by a certified service technician.
Many repairs may only be done by a certified service technician.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents