Troubleshooting System Cooling Problems; Troubleshooting A Fan - Dell PowerEdge T300 Series Hardware Owner's Manual

Hardware owner's manual (pdf)
Hide thumbs Also See for PowerEdge T300 Series:
Table of Contents

Advertisement

Troubleshooting System Cooling Problems

Problem
Systems management software issues a fan-related error message.
Action
Ensure that none of the following conditions exist:
System cover, drive blanks, or shrouds are removed.
Ambient temperature is too high.
External airflow is obstructed.
Cables inside the system obstruct airflow.
An individual cooling fan is removed or has failed (see "Troubleshooting a
Fan" on page 145).

Troubleshooting a Fan

Problem
Systems management software issues a fan-related error message.
Front panel LCD indicates a problem with the fan.
Action
CAUTION:
Only trained service technicians are authorized to remove the system
cover and access any components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
1 Run the appropriate diagnostic test (see "Using Dell PowerEdge
Diagnostics" on page 163).
2 Turn off the system and attached peripherals, and disconnect the system
from the electrical outlet and peripherals.
3 Open the system (see "System Cover" on page 66).
4 Locate the faulty fan indicated by the LCD display or diagnostic software.
For the identification number of each fan, see "Cooling Fans" on page 106.
Troubleshooting Your System
145

Advertisement

Table of Contents
loading

Table of Contents