Specifi cations –––––––––––––––––––––––––––––––––––––––––––––––––––
Dimensions
Width
Depth
Height
Unit Shipping Weight
Ambient Information
CAUTION!
The E7UC100A and E7UD100A are for indoor use only.
Air Temperature*
Water Temperature
Water Pressure
Relative Humidity
* Best performance is achieved between 27 C (80 F) and 10 C (50 F).
Plumbing
§ Water Inlet: 1/4" MPT
§ Optional Drain Accessory Kit (item# 00956375): 1/2" ID tubing
§ Water shut-off recommended within 1.5 m (5 ft) of dispenser.
Water
WARNING!
Connect to potable water supply only.
§ Water Mineral Content:
– TDS: greater than 5 ppm (mg/l) but less than 400 ppm (mg/l)
– Hardness: Less than 200 mg/l (12 gpg)
§ Not recommended for use with softened water
§ Ingress Protection (IP) rating: IPX0 (no protection)
Clearances
§ 77 mm (3") behind dispenser for electrical and optional drain connection.
§ 15.3 cm (6") in front of dispenser for ventilation.
Electrical
§ 230V, 50 Hz, 1 phase, 5A, maximum fuse 10A
§ Connect to dedicated 15A circuit, fuse or breaker. Note: It is preferred that circuit be protected by a GFCI.
§ Replacement cord instructions, type IEC 60320-C13 attachment - If the supply cord is damaged, it must
be replaced by a special cord or assembly available from the manufacturer or its service agent.
Refrigeration
WARNING!
Do not damage the refrigerant circuit. Refrigerant can cause personal injury and/or damage
dispenser.
§ Refrigerant R134a – 204 grams (7.2 oz.)
Heat Rejection
§ 498 W (1700 BTU/hr)
E7UC100A
37 cm (14.55")
56 cm (22.05")
85.1 cm (33.50")
50 kg (110 lb)
Maximum
38 C (100 F)
32.2 C (90 F)
70 psi
Undercounter Dispenser and Ice machine E7UC100A/E7UD100A
37 cm (14.55")
56 cm (22.05")
80 cm (31.50")
50 kg (110 lb)
10 C (50 F)
4.5 C (40 F)
10 psi
55% at 25.5 C (78 F)
E7UD100A
Minimum
5