Connecting Alarms

Document 800-07067V4 Rev A
11/2011
®
HCD5 EQUIP
Series True Day/Night Network Box Camera Reference Guide
WARNING!
Do not exceed the maximum rating of 12V DC, 0.5 A on alarm
output connections.
The network camera has one alarm input and one alarm output available to connect to
peripheral devices
(Figure
Figure 2-4
Alarm Connections
OUT
OUT
IN
IN
ALARM
Connect mechanical or electrical switches to the alarm input connection to allow
event-triggered recording. When alarm inputs are configured, the camera triggers an alarm
only when the normal state (open or closed) changes (see
on page
59
to configure the alarm inputs.
The network camera has a LAMP setting which allows control of the moving IR cut filter
when there is a change in state from Normally Open to Normally Closed (see
on page
59
for more information). In this way, the moving IR cut filter and the day/night
operation of the camera can be synchronized with external lighting changes using a
common controller such as a photocell or timer.
Figure 2-5
Normal Alarm States
Normally opened
Normally closed
Connect external devices such as sirens or flashing lights to the alarm output connector to
signal users of the camera that an alarm is activated. See
2-4).
Figure
2-5). See
Alarm Settings
Alarm Settings
Figure 2-6
for alarm connection.