Send Diagnostic Command (1D H ) - Seagate MEDALIST 1080SL Product Manual

Scsi interface drive
Hide thumbs Also See for MEDALIST 1080SL:
Table of Contents

Advertisement

52
Medalist 1080sl SCSI Product Manual, August 1995
The vendor-unique error codes are listed in Section
Byte 7
3.4.15.2.
3.4.15.2 Diagnostic error codes
The following diagnostic error codes are reported in byte 7 of the
diagnostic data format in Section 3.4.15.1.
Error code
Description
01
Sequencer test error
H
02
Microprocessor RAM diagnostic error
H
09
Fatal hardware error during drive diagnostics
H
44
EEPROM test error
H
80
Buffer controller diagnostic error
H
81
Buffer RAM diagnostic error
H
3.4.16 Send Diagnostic command (1D
When the drive receives this command, it performs diagnostic tests on
itself. In systems that support disconnection, the drive disconnects while
executing this command.
Bytes
7
6
0
0
0
1
LUN = 0
2
0
0
3–4 (default)
5
0
0
Byte 1
If the PF (Page Format) bit is set to 0 and the self test bit is
1, the drive performs the buffer RAM diagnostics, which is
the default self-test. If the default self- test is requested, the
parameter list length is 0 and no data is transferred. If the
self-test passes successfully, the command terminates with
a good status. If the self-test fails, the command terminates
with a check condition status and the sense key is hardware
error.
)
H
Bits
5
4
3
2
0
1
1
1
Self
PF
0
Test
0
0
0
0
Parameter list length (00
H
0
0
0
0
1
0
0
1
Dev
Unit
OfL
OfL
0
0
)
0
0