Medalist 1080sl SCSI Product Manual, August 1995
3.4.15 Receive Diagnostic Results command (1C
When the drive receives the Receive Diagnostics command after power-
up or after a Send Diagnostic command with PF=0, it sends eight
diagnostic data bytes to the initiator. The initiator sends the Receive
Diagnostic Results command after the drive completes the Send Diag-
nostic command. The page length is describe in the Send Diagnostics
command. The most recent Send Diagnostic command determines the
data returned by the Receive Diagnostic Results command.
Bytes
7
6
0
0
0
1
LUN = 0
2
0
0
3–4
5
0
0
Bytes 3–4 The allocation length specifies the number of bytes the
initiator has allocated for returned diagnostic result data. An
allocation length of 0 means that no diagnostic data is
transferred. The drive sends the allocation length or the
bytes available, whichever number is less.
3.4.15.1 Diagnostic data format
Bytes
7
6
0–1 (default)
2–5
6
7
Byte 0–1
The additional length value indicates the number of addi-
tional bytes included in the diagnostic data list. A value of
0000
means that there are no additional bytes. A value of
H
0006
means that no product-unique bytes are available.
H
Bytes 2–5 If the field replaceable unit (FRU) code is 00
FRU information. If the FRU code is 01
Other values are drive-unique.
Byte 6
The diagnostic error code is not supported.
Bits
5
4
3
2
0
1
1
1
0
0
0
0
0
0
0
Allocation length
0
0
0
0
Bits
5
4
3
2
Additional length (0006
)
H
FRU code
Diagnostic error code
Vendor-unique error code
, replace the drive.
H
51
)
H
1
0
0
0
0
0
0
0
0
0
1
0
, there is no
H

Advertisement