Stopping The Zywall; Rack-Mounting - ZyXEL Communications ZyWALL USG Series User Manual

Unified security gateway
Hide thumbs Also See for ZyWALL USG Series:
Table of Contents

Advertisement

Chapter 1 Introduction
Figure 17 Working with Lists

1.5 Stopping the ZyWALL

Always use Maintenance > Shutdown > Shutdown or the shutdown command before you turn
off the ZyWALL or remove the power. Not doing so can cause the firmware to become corrupt.

1.6 Rack-mounting

See
Table 1 on page 5
steps to mount the ZyWALL on an EIA standard size, 19-inch rack or in a wiring closet with other
equipment using a rack-mounting kit. Make sure the rack will safely support the combined weight of
all the equipment it contains and that the position of the ZyWALL does not make the rack unstable
or top-heavy. Take all necessary precautions to anchor the rack securely before installing the unit.
Note: Leave 10 cm of clearance at the sides and 20 cm in the rear.
Use a #2 Phillips screwdriver to install the screws.
Note: Failure to use the proper screws may damage the unit.
Align one bracket with the holes on one side of the ZyWALL and secure it with the included bracket
1
screws (smaller than the rack-mounting screws).
Attach the other bracket in a similar fashion.
2
After attaching both mounting brackets, position the ZyWALL in the rack and up the bracket holes
3
with the rack holes. Secure the ZyWALL to the rack with the rack-mounting screws.
20
for the ZyWALL USG models that can be rack mounted. Use the following
ZyWALL USG 20-2000 User's Guide