Report Console Trouble; Report Force Arming; Opening And Closing Reports; Point Id Reporting - Linear DVS 1200 Installation Instructions Manual

Supervised wireless security console
Table of Contents

Advertisement

REPORT CONSOLE TROUBLE

The factory setting does not report Console
trouble events to the Central Station.
Alternately, the communicator can be
programmed to report Console trouble events.
These include all conditions that light the
Console's BATTERIES or TROUBLE indicator.
It also includes low Console backup battery.

REPORT FORCE ARMING

The factory setting does not send force arming
reports.
Alternately, the communicator can be
programmed to report force arming anytime
the Console is armed with one or more
bypassed sensors.
The factory set reporting code for force
arming is "65" (Code 574 with Ademco).
NOTE: If force arming is enabled, and the Console
is force armed (armed with an open sensor)
remotely by telephone, or with the RA-2400
Remote Access software, the caller will be
disconnected if the communicator is enabled.

OPENING AND CLOSING REPORTS

The factory setting does not send opening and
closing reports
Alternately, the communicator can be
programmed to send an opening report when
the system is disarmed, and a closing report
when the system is armed for all users, or just
the master user.
NOTE 1: For commercial installations using
opening and closing reports, it is recommended to
disable quick arming to prevent customers from
arming the system.
NOTE 2: The reporting codes are fixed for opening
and closing. A unique code is reserved for the
master user code and each of the five restricted
user codes.
NOTE 3: The page alert user code has a closing
code reserved. Disarming with the page alert user
code dials the supervisory number, no opening
report is sent.

POINT ID REPORTING

The factory setting enables Point ID and
allows the communicator to send two-digit
alarm and trouble codes for each sensor. The
individual sensor that causes an alarm or
trouble report can be identified at the Central
Station.
Alternately, Point ID can be disabled. The
Central Station will only receive general alarm
and trouble reports.
PROGRAMMING STEP #108
PROGRAM
0 FOR NO CONSOLE TROUBLE
1 FOR CONSOLE TROUBLE
STORE PROGRAM
PROGRAMMING STEP #110
PROGRAM
0 FOR NO FORCE ARMING RPTS.
1 FOR FORCE ARMING RPTS.
STORE PROGRAM
PROGRAMMING STEP #111
PROGRAM
0 FOR NO OPEN/CLOSE REPORTS
1 FOR O/C RPTS. FOR ALL USERS
2 FOR O/C RPTS. FROM MASTER
USER ONLY
STORE PROGRAM
PROGRAMMING STEP #113
PROGRAM
0 FOR GENERAL REPORTS ONLY
1 FOR POINT ID REPORTING
STORE PROGRAM