REPORTING FORMAT

The factory setting causes the communicator
to report using the 4 by 2 format. This format
allows four-digit account numbers from 0000
to 9999 and provides two-digit alarm codes.
Alternately ADEMCO CONTACT ID can be
chosen as a reporting format. This format allows
4-digit account numbers from 0000 to 9999
and provides verbose report descriptions with
Ademco Contact ID compatible Central Stations.

CALL ROUTING

The factory setting for the communicator is to
route all calls to the primary telephone
number. If communication is unsuccessful
after five attempts to the primary number, the
secondary number will be dialed for an
additional five attempts. If the secondary
number cannot be reached, the communicator
will "sleep" for five minutes before starting the
call process over again. A total of five sleep
cycles (50 call attempts) can occur before the
communicator stops calling.
Alternately, the communicator can be
programmed to report supervisory events (low
batteries, radio trouble, AC failure, etc.) to the
supervisory telephone number instead of the
primary or secondary telephone numbers.
CAUTION: If the page alert user code feature is
going to be used, the supervisory number is
reserved for the pager number. DO NOT SET THE
CALL ROUTING OPTION TO "1".
To disable supervisory reports, set call routing
option to "1" and remove the supervisory
telephone number or in 4 by 2 set the report to "0".
NOTE: Do not program the primary and secondary
telephone numbers the same. See the FCC
Telephone Rules and Regulations on the rear
cover of this manual.
PROGRAMMING
STEP #
FUNCTION
86
CALL ROUTING
88
ACCOUNT NUMBER
89
PRIMARY PHONE NUMBER
90
SECONDARY PHONE NUMBER
91
SUPERVISORY/ PAGER PHONE NUMBER
FOR ALL PHONE NUMBERS
105
REPORTING FORMAT
108
REPORT CONSOLE TROUBLE
110
REPORT FORCE ARMING
111
OPEN/CLOSE
113
POINT ID REPORTING FOR 4 BY 2 FORMAT

COMMUNICATOR REPORTING OPTIONS

COMMUNICATOR REPORTING OPTIONS
POSSIBLE
0 = ALL CALLS TO PRIMARY OR SECONDARY NUMBER
1 = ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND
ALL OTHERS TO SUPERVISORY NUMBER
4 DIGITS
UP TO 20 DIGITS
UP TO 20 DIGITS
UP TO 20 DIGITS
PRESSING THE (A) KEY INSERTS A 1-SECOND DELAY
THE [FIRE] KEY INSERTS A 5-SECOND DELAY
THE [CHIME] KEY INSERTS A "
"
*
THE (A) KEY INSERTS A "#" IF IT IS THE LAST DIGIT OF THE PHONE NUMBER
0 = 4 BY 2; 1 = ADEMCO
0 = NO; 1 = YES
0 = NO; 1 = YES
0 = NO; 1 = YES; 2 = MASTER PAC ONLY
0 = NO; 1 = YES
Communicator Reporting Option Table
1
PROGRAMMING STEP #105
0
5
JKL
PROGRAM
HOME
0 FOR 4 BY 2
1 FOR ADEMCO CONTACT ID
AWAY
STORE PROGRAM
8
TUV
PROGRAMMING STEP #86
6
MNO
PROGRAM
HOME
0 FOR ALL TO PRIMARY/SECONDARY
1 FOR ALARMS ONLY TO
PRIMARY/SECONDARY
AWAY
STORE PROGRAM
VALUES
INSTALLATION
FACTORY VALUE
VALUE
0
EMPTY
EMPTY
EMPTY
EMPTY
0
0
0
0
1
35