AUTOMATION OUTPUT MODE DURING ALARM

NOTE: For the Automation Output to activate
during an alarm, that function must be enabled
with Programming Step 71 or 72.
If the Automation output is programmed to
activate during an alarm, it can be
programmed to flash or be steady.

AUTOMATION ACTIVATION TONE

The factory setting causes the Console to
sound a "bing" when the Automation Output
is activated by pressing the [ (A) ] key, or when
it's triggered with a two-button remote control.
Alternately, this sound can be silenced.

REMOTE CONTROL ARM/DISARM CHIRP

When arming with the portable remote
control, the factory setting causes the Console
to "chirp" once when armed, twice when
disarmed, and three times when arming with
sensors bypassed.
Alternately, these chirps can be silenced.
NOTE: If these chirps are silenced, it is
recommended to program the Automation Output
to be active when the system is armed, so a light
can be triggered displaying the arming status of
the Console.

AUTOMATION OUTPUT FLASHES DURING AND AFTER ALARM

The factory setting causes the Console's
Automation Output to activate when pressing
the [ (A) ] key, or when it's triggered with a
two-button remote control.
In addition, the Console can be programmed
to flash the Automation Output during and
after any alarms.
The output will continue to flash until the
flashing status lights are cleared.

AUTOMATION OUTPUT ON DURING ALARM

The factory setting causes the Console's
Automation Output to activate when pressing
the [ (A) ] key, or when it's triggered with a
two-button remote control.
In addition, the Console can be programmed
to activate the Automation Output during
alarms.
NOTE: The Automation Output can be
programmed to flash or be steady during alarm,
see Programming Step 68.
6
MNO
PROGRAMMING STEP #68
8
TUV
PROGRAM
HOME
0 FOR FLASHING OUTPUT ON ALARM
1 FOR STEADY OUTPUT ON ALARM
STORE PROGRAM
AWAY
6
MNO
PROGRAMMING STEP #69
9
WXY
PROGRAM
HOME
0 FOR BING TONE OFF
1 FOR BING TONE ON
AWAY
STORE PROGRAM
7
PRS
PROGRAMMING STEP #70
0
PROGRAM
HOME
0 FOR CHIRPS OFF
1 FOR CHIRPS ON
AWAY
STORE PROGRAM
7
PRS
PROGRAMMING STEP #71
1
PROGRAM
HOME
0 FOR STANDARD TRIGGER
1 FOR FLASHING DURING
& AFTER ALARM
AWAY
STORE PROGRAM
7
PRS
PROGRAMMING STEP #72
2
ABC
PROGRAM
HOME
0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING ALARM
STORE PROGRAM
AWAY
29