COMMUNICATOR ENABLE

The factory setting for the Console disables
the communicator. If the system is going to be
a non-monitored, local alarm only, leave the
communicator disabled.
If the system is going to be monitored by a
Central Station, enable the communicator with
this programming step.

2-WAY AUDIO

When the Model VB-2 audio module is
installed, the communicator can provide
2-way audio capability.
The audio module can be programmed for
listen only, 2-way manual operation (using a
pushbutton telephone at the Central Station),
and 2-way full duplex hands free operation.
Refer to the VB-2 installation instructions for
details on operating the audio module.
NOTE: The Model VB-2 Digital Voice Synthesis
module must be installed for this option to
function.
The factory setting for the VB-2 audio module
is OFF.
Alternately, the audio module can be set for
(1) listen-only, (2) 2-way manual, (3) 2-way
full duplex.

VOICE RESPONSE

The Console can be programmed to allow its
speaker to play audio produced by the VB-2
or VB-3 digital voice synthesis modules.
This selection can also be used when a remote
speaker is connected to the Console.
The factory setting is to disable the Console's
speaker from playing voice module audio.
Alternately, the Console can be programmed
to enable voice module audio.
NOTE: Turning voice response OFF with this
programming step will only effect the audio
produced by the voice module. It will not stop the
Console's speaker from sounding local sirens and
tones.
NOTE: A Model VB-2 or VB-3 Digital Voice
Synthesis module must be installed for this option
to function.

REMOTE LOCKOUT

The factory setting for the communicator is to
allow remote connection to the Console with
Linear's RA-2400 Remote Access Software
and a modem (unlocked).
Alternately, the Console can be programmed
to not answer incoming calls, thereby, not
allowing remote access (locked).

GENERAL COMMUNICATOR OPTIONS

1
0
PROGRAMMING STEP #107
7
PRS
PROGRAM
HOME
0 FOR COMMUNICATOR OFF
1 FOR COMMUNICATOR ON
AWAY
STORE PROGRAM
7
PRS
PROGRAMMING STEP #76
6
MNO
PROGRAM
HOME
0 FOR NO AUDIO MONITORING
1 FOR LISTEN-ONLY
2 FOR 2-WAY MANUAL
3 FOR 2-WAY FULL DUPLEX
AWAY
STORE PROGRAM
7
PRS
PROGRAMMING STEP #78
8
TUV
PROGRAM
HOME
0 FOR NO VOICE RESPONSE
1 FOR VOICE RESPONSE
AWAY
STORE PROGRAM
1
0
PROGRAMMING STEP #100
0
PROGRAM
HOME
0 FOR UNLOCK
1 FOR LOCK
AWAY
STORE PROGRAM