Safety Precautions; Leakage Current Check; Ac Leakage Test; Leakage Testing - Harman Kardon AVR145 Service Manual

5 x 40w 5.1 channel a/v receiver
Hide thumbs Also See for AVR145:
Table of Contents

Advertisement

AVR145

SAFETY PRECAUTIONS

The following check should be performed for the continued
protection of the customer and service technician.

LEAKAGE CURRENT CHECK

Measure leakage current to a known earth ground (water
pipe, conduit, etc.) by connecting a leakage current tester
between the earth ground and all exposed metal parts of the
appliance (input/output terminals, screwheads, metal
overlays, control shaft, etc.). Plug the AC line cord of the
appliance directly into a 120V AC 60Hz outlet and turn the
AC power switch on. Any current measured must not exceed
o.5mA.
Device
under
test
Test all
exposed metal
surfaces
Also test with
plug reversed
(Using AC adapter
plug as required)

AC Leakage Test

ANY MEASUREMENTS NOT WITHIN THE LIMITS
OUTLINED ABOVE ARE INDICATIVE OF A
POTENTIAL SHOCK HAZARD AND MUST BE
CORRECTED BEFORE RETURNING THE APPLIANCE
TO THE CUSTOMER.
Reading should
not be above
Leakage
0.5mA
current
tester
Earth
ground
3