5. Remove the front-page lamp housing by grasping the black handle
and gently pulling it out of the scanner.
6. Carefully remove each lamp out of the housing.
7. Do one of the following:
• If you are replacing the lamps, discard the lamps in accordance
with your local regulations. It is suggested that you replace lamps
in pairs.
• If you are cleaning the lamps, use a soft cloth and carefully wipe
the lamps until they are free of dust.
8. Insert the new or clean lamp(s) back into the housing.
9. Slide the lamp housing back into the side frame of the scanner until
it stops.
10. Repeat steps 4 through 7 to remove and clean the back-page
lamps.
NOTE: After cleaning, if the lamps do not operate or the light
source is still degraded, re-check the position of the lamps
and housing(s). Improperly installed lamps are a common
cause of these conditions.
11. Close the side access panel.
12. Close the scanner transport cover.
13. Power up the scanner.
14. If you replaced the lamps, continue with Step 14. If you only cleaned
the lamps, go to Step 15.