Location - Henny Penny BCC/BCR-140 Service Manual

Blast chiller/freezer
Hide thumbs Also See for BCC/BCR-140:
Table of Contents

Advertisement

Henny Penny
2-3. ELECTRICAL
(Continued)

2-4. LOCATION

201
Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350
Refer to the table below for electrical ratings for both models.
Model No.
Volts
BCC-140
208-240
BCC-175
208-240
BCR-140
208-240
BCR-175
208-240
BFR &
BCR-350
208-240
The Blast Chillers should be placed in an area where the doors can
be opened, for loading and unloading, without interruption. For
proper operation, the cabinet must be level.
For maximum efficiency, if the air temperature of the premises
is more than 100° F (38° C), the room should have adequate
ventilation, taking into account for the heat emitted by the unit.
Clearances should be as follows:
BCC/BCR-140 Top ........... 16 in. (400 mm) for air circulation
Left Side ... 4 in. (100 mm) for air circulation
Right Side . 8 in. (200 mm) for air circulation
Back ......... 4 in (100 mm) for air circulation
Front ........ 26 3/8 in (668 mm) for door swing
BCC/BCR-175 Top ........... 16 in. (400 mm) for air circulation
Sides ........ 3 in. (70 mm) for air circulation
Front ........ 33 3/8 in. (847 mm) for door swing
BFR &
Top ........... 16 in. (400 mm) for air circulation
BCR-350
Sides ........ 3 in. (70 mm) for air circulation
- Front and Back ... 38 1/8 in (970 mm) for door swing
Pass Thru
-Front ................... 38 1/8 in. (970 mm) for door swing
Solid Back
Back ................... 4 in. (100 mm) for air circulation
Watts
Amps
200
4700
18
4700
18
230
4700
20
200
5800
20
5800
20
400
5800
9
2400
12
230
2400
10
200
2400
12
200
2400
12
2400
12
230
2400
12
200
4100
15
4100
15
400
4100
10
Freq. Phase
50/60
3
60
3
50
1
50/60
3
60
3
50
3N
60
1
50
1
50-60
1
50/60
1
60
1
50
1
50/60
3
60
3
50
3N
2-3