2-5. REFRIGERANT
INFORMATION
2-6. REFRIGERATION
CAPACITIES
2-4
Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350
Refrigerant Type Amount of Refrig.
BCC-140
R404A
BCC-175
R404A
BCC/BCR-140
-4
F (-20
C) at 6,800 BTU/hr (2.0 kw)
o
o
32
F (0
C) at 16,000 BTU/hr (4.7 kw)
o
o
BCC/BCR-175
-4
F (-20
C) at 11,300 BTU/hr (3.3 kw)
o
o
32
F (0
C) at 38,800 BTU/hr (9.0 kw)
o
o
BCR-350
-4
F (-20
C) at 25,000 BTU/hr (7.3 kw)
o
o
32
F (0
C) at 58,000 BTU/hr (17.0 kw)
o
o
BFR-350
-4
o
F (-20
o
C) at 81,900 BTU/hr (24.0 kw)
-40
F (-40
o
o
6 lbs. (2.7 kg)
5.5 lbs. (2.4 kg)
C) at 35,500 BTU/hr (10.4 kw)
Design Pressure
High
Low
406 psig
102psig
(28 bar)
(7 bar)
406 psig
102 psig
(28 bar)
(7 bar)
201