3-7. PROGRAMMING

00
01
02
03
04
05
300
Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350
Information about the operation settings can be accessed by
pressing the Alarm button. These settings can also be changed
while in the different steps. The following information can be
accessed:
After pressing the Alarm button, a delay will occur before
the desired number will appear in the display, and the
number in the left column will show for 2 seconds. You then
only have 12 seconds to change the setting.
1. Not Available at this time.
2. Not Available at this time.
3. Internal air temperature. Press the Alarm button three
times and the digital display will show the air temperature
during a food probe cycle.
4. Evaporator temperature. Press the Alarm button 4 times
and the digital display will show the evaporator tempera-
ture during the de-icing cycle.
5. Type of program setting indicated by the jumper
link located on the control board. Press the Alarm
button 5 times and the digital display will show a number
between 5 and 9, which indicates the position of the jumper
on the control board. The control panel area does not have
to be accessed to obtain the information.(See chart at left).
Henny Penny controls should show a "6" in the display.
6. Temperature of the holding cycle, after the chilling. Press
the Alarm button 6 times and the digital display will show the air
temperature. This is the temperatures the unit will stay at during
the hold cycle.
NOTE