Error Codes - Henny Penny ROTISSERIE SCR-6/8 Operator's Manual

Henny penny corp. convection oven user manual
Table of Contents

Advertisement

6-2. ERROR CODES

DISPLAY
"E-4"
"Prob Err"
"E-6"
"ctrl hot"
"E-50" "CPU Chip"
"E-51" "rA-CHIP"
"E-53" "ro-CHIP"
"E-41" "data Err"
"E-5" "too hot"
203
CAUSE
• Control board too hot;
blower wheel clogged
or not working
• Temperature probe
failure
• CPU RAM Error
•External RAM error
• External ROM error
• Scrambled Memory
• Software high limit
(Air Temperature too hot)
PANEL BOARD CORRECTION
• Clean or have blower replaced
• Check probe connection at board, or
have probe replaced
• "E-50", "E-51", "E-53", and "E-41"
reinitialize the
are software errors;
board, and if error persists, replace
control board
• Have control board and contactor
checked or replaced
• Have blower checked and replaced if
necessary
SCR-6/8
6-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rotisserie scr-6Rotisserie scr-8