All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the
Wiring Rules AS/NZS 3000 and local authority requirements.
Warning: Temperature controllers must not be fitted to this water heater (864 series) as part of a solar
water heater system or if a Water Star water heater is installed because water at a temperature much higher
than the controller setting can be delivered. If a solar preheater or Water Star water heater has been installed
to an existing water heater installation, then all controllers must be disconnected and removed.
The water heater is supplied with a 1.8 metre lead and plug and requires a 240 V 50 Hz general purpose
outlet (GPO) to be located within 1.2 metres of the installation. The GPO must be clear of the flue exhaust,
draining water, gas supply pipe and water connections.
The power consumption of the water heater is:
Component
Gas water heater
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot be
used to supply power to the water heater.
CONNECTIONS – ELECTRICAL
Power
consumption
80 Watts
027 – Burner on, anti frost device inactive
187 Watts
027 – Burner on, anti frost device active
Comments
74