  • Page 1: Owners Guide

    Owners Guide Installation Instructions Gas Heavy Duty Water Heater 260 Litre Models This water heater must be installed and serviced by an authorised person. Please leave this guide with a responsible officer.
  • Page 2 Only a licensed person will give you a Complia.(y).in8 T6 0.Ciceat, shCono tat. PATENTS This water heater may be protected by one or more patents or registered designs. ® Registered trademark of Rheem Australia Pty Ltd. ™ Trademark of Rheem Australia Pty Ltd.
  • Page 3: Table Of Contents

    HOUSEHOLDER – We recommend you read pages 4 to 13. The other pages are intended for the installer but may be of interest. About Your Water Heater...4 How Your Water Heater Works...8 Regular Care ...9 Save A Service Call ...11 Installation...14...
  • Page 4: About Your Water Heater

    This will keep the water temperature below 50°C at the bathroom and ensuite. The risk of scald injury will be reduced and still allow hotter water to the kitchen and laundry.
  • Page 5 Do not store swimming pool chemicals, household cleaners, etc., near the water heater. • Do not place anything on top of the water heater or in contact with the draught diverter or flue terminal. Ensure the flue terminal is not obstructed in any way at any time.
  • Page 6 Close the cold water isolation valve at the inlet to the water heater. TO TURN ON THE WATER HEATER • Open the cold water isolation valve fully at the inlet to the water heater. • Open the gas isolation valve fully at the inlet to the gas control.
  • Page 7 ANODE PROTECTION The anode(s) installed in your water heater will slowly dissipate whilst protecting the cylinder. The life of the water heater cylinder may be extended by arranging for an authorised person to inspect the anode(s) and replace if required.
  • Page 8: How Your Water Heater Works

    A flue baffle in this flue ensures the efficiency of the water heater is correct. The gas supply to the burner is controlled by the thermostat so the water is heated to a constant temperature.
  • Page 9: Regular Care

    – line lower gently the Rheem Service Department or their Accredited Service Agent. The temperature pressure relief valve should be checked for performance or replaced at intervals not exceeding 5 years, or more frequently in areas where there is a high incidence of water deposits (refer to “Water Supplies”...
  • Page 10 SERVICING For safe and efficient operation, the water heater should be serviced annually by your nearest Rheem Service Department or their Accredited Service Agent. Only genuine replacement parts should be used on this water heater. Warning: Servicing of a gas water heater should only be carried out by authorised personnel.
  • Page 11: Save A Service Call

    • Water heater size Do you have the correct size water heater for your requirements? The sizing guide in the Rheem sales literature and on the Rheem website (www.rheem.com.au) WATER NOT HOT ENOUGH You may find that due to heavy hot water usage the water temperature may be lower than normally expected.
  • Page 12 Heavy flows of hot water until the water heater is cold - then stops until water reheats The gas control must be turned off using the knob on top of the gas control thermostat (refer to nearest Rheem Service Department or Accredited Service Agent to arrange for inspection. Pressure water “Close Down Procedure”...
  • Page 13 SAVE A SERVICE CALL EXPANSION CONTROL VALVE RUNNING If an expansion control valve is fitted in the cold water line to the water heater (refer to page 23) it may discharge a small quantity of water instead of the temperature pressure relief valve on the water heater. The benefit is that energy is conserved as the discharged water is cooler.
  • Page 14: Installation

    NZS 5261 Code of Practice for Installation of Gas Burning Appliances and the New Zealand Building Code. The water heater must not be installed in an area with a corrosive atmosphere where chemicals are stored or where aerosol propellants are released.
  • Page 15 The flue must be self supporting and not impose a load on the water heater. Use a slip joint or similar to allow for disconnection. There must be a vertical rise of 600 mm from the draught diverter before changing direction.
  • Page 16 OUTDOOR INSTALLATION The water heater is to be installed at ground level on a concrete or brick plinth (fire proof base) and must stand vertically upright with the back of the water heater against an external wall or alternatively against a fireproof...
  • Page 17 * Expansion control valve not supplied with the water heater. TANK WATER SUPPLY If the water heater is supplied with water from a tank supply, then the bottom of the supply tank must be at least 1 m above the highest hot water outlet. Take care to avoid air locks.
  • Page 18 Two Temperature Zones Using a Temperature Limiting Device CIRCULATED HOT WATER FLOW AND RETURN SYSTEM If a Rheem water heater is to be installed as part of a circulated hot water flow and return system, a storage water heater able to provide a hot water outlet temperature of at least 60°C must be used.
  • Page 19 Circulated Hot Water Flow and Return System – Gas Water Heater REDUCING HEAT LOSSES The cold water line to and the hot water line from the water heater must be insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed.
  • Page 20 DIMENSIONS AND TECHNICAL DATA Indoor Model Storage capacity litres Mass (tank) Empty Full Hourly Gas Gas Details Consumption (MJ) 620 260, 630 260 Natural Propane Butane Town / TLP 40/36 Model numbers: N = Natural, P = Propane, B = Butane, T = Town / TLP. Letter N, P, B or T is included in the model number, eg 620260N0, to denote gas type.
  • Page 21 INSTALLATION TYPICAL INSTALLATION – INDOOR LOCATION...
  • Page 22 INSTALLATION TYPICAL INSTALLATION – OUTDOOR LOCATION...
  • Page 23: Connections - Plumbing

    WATER INLET AND OUTLET All pipe work must be cleared of foreign matter before connection and purged before attempting to operate the water heater. All olive compression fittings must use brass or copper olives. Use thread sealing tape or approved thread sealant on all fittings.
  • Page 24 Damaged valves must be replaced. PIPE SIZES The cold water pipe to the water heater should be the same size or bigger than the hot water line from the water heater. The pipe sizing for hot water supply systems should be carried out by persons competent to do so, choosing the most suitable pipe size for each individual application.
  • Page 25 The pipe work from the relief valve to the drain should be as short as possible and fall all the way from the water heater with no restrictions. It should have no more than three right angle bends in it. Use DN20 pipe.
  • Page 26: Multiple Installations

    MULTIPLE INSTALLATIONS A multiple installation of Rheem water heaters on a single manifold or multiple manifolds is possible, using the Rheem Equa-Flow large volumes of hot water are required. The Equa-Flow principle will function with water heaters in line, around a corner or in rows back to back diagrams on page 27).
  • Page 27 MULTIPLE INSTALLATIONS In Line Manifold Single Bank of Water Heaters Multiple Banks of Water Heaters Angle Manifold Back to Back Manifold TPR Valve Drain Line Common Discharge Point...
  • Page 28 MULTIPLE INSTALLATIONS LEGEND TYPICAL INSTALLATION – RHEEM HEAVY DUTY GAS WATER HEATERS...
  • Page 29 In Line Manifold NOTES: 1. Minimum 2. A minimum of 900 mm (E* & F*) Back to Back Manifold INSTALLATION DIMENSIONS – RHEEM HEAVY DUTY GAS WATER HEATERS recommended space between wall and back of water heater is 100 mm.
  • Page 30 MULTIPLE INSTALLATIONS MANIFOLD ARRANGEMENT Hot Manifold Assembly Cold Manifold Assembly...
  • Page 31: Commissioning

    COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The gas pilot or burner must not be lit until the water heater is filled with water. • Open all of the hot water taps in the building (don’t forget the showers) and supply cock(s) and valve(s) in the system.
  • Page 32 COMMISSIONING TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater on completion of the installation, such as on a building site or where the premises is vacant, then: • Shut down the gas control (refer to •...
  • Page 33: Lighting The Water Heater

    If the gas smell is throughout the area, turn the gas control knob clockwise to the “ ” (off) position and then turn off the isolation valve on the gas line to the water heater. Leave the area and call Rheem Service or a qualified service technician.
  • Page 34 60°C. If this water heater is installed as an in-series booster water heater as part of a commercial solar water heating system, then Rheem recommends the thermostat is set at 60°C to maximise solar contribution. 10. Refer to “Temperature Adjustment”...
  • Page 35 Check the test point pressure and compare with the rating label. The pressure regulator is not adjustable and if the test point pressure is not within 5% of the specified value, refer to Rheem or their Accredited Service Agent. •...
  • Page 36 LIGHTING THE WATER HEATER CLOSE DOWN PROCEDURE Turn the gas control knob to the “ ” position (pilot). This setting will leave the pilot flame alight however the main burner will not be able to light. Turn the gas control knob to the "...
  • Page 37: Draining The Water Heater

    Let the other end of the hose go to a drain. • Open the drain cock. • Operate the relief valve again. This will let air into the water heater and allow the water to drain through the hose. “To Turn Off The Water Heater”...
  • Page 38: Water Supplies

    In areas where the total dissolved solids (TDS) exceeds 600 mg/L it is possible the black anode, which is the standard anode fitted to the water heater, may be excessively active. To alleviate this, the black anode should be replaced with one colour coded blue.
  • Page 39: Warranty

    Accredited Service Agent, the cost of transport, insurance and travelling costs between the nearest Rheem REPAIR AND REPLACEMENT WORK WILL BE CARRIED OUT AS SET OUT IN THE RHEEM WATER HEATER WARRANTY, HOWEVER THE FOLLOWING EXCLUSIONS MAY CAUSE THE WATER HEATER WARRANTY TO BECOME VOID AND MAY INCUR A SERVICE CHARGE AND / OR COST OF PARTS.
  • Page 40 ** Refer to items 4 and 5 of warranty conditions. Rheem reserves the right to transfer fully functional components from the defective water heater to the replacement water heater if required. The term “water heater” used in the Warranty, Warranty Conditions and Warranty Exclusions means the Rheem supplied water heater(s), solar storage tank(s), solar collector(s), kit(s) and components.

This manual is also suitable for:

620260630260

Table of Contents