MAINS PRESSURE

The water heater is designed for direct connection to the mains water supply. If the mains supply pressure in
your area exceeds that
should be greater than 140 kPa for the rated flow and performance to be achieved.

HOW HOT SHOULD THE WATER BE?

The water heater may be installed with one or more user
adjustable temperature controllers, which allow you to choose
the most suitable temperature for your hot water needs (refer
to
"Temperature
Control"
If a controller is not installed, the water heater heats the water
to the preset outlet temperature setting. The factory preset
outlet temperature setting is:
864 series
The preset outlet temperature setting of this water
Note:
heater cannot be adjusted by the householder. The setting
can only be adjusted by the installer, your nearest Rheem
Service Department or their Accredited Service Centre.
If this water heater is installed as part of a solar water heater
system, the installer has checked and if required, adjusted
the preset outlet temperature setting of an 864 series water
heater to 55°C.
Warning: Temperature controllers must not be fitted to
this water heater (864 series) as part of a solar water heater system installation because water at a
temperature much higher than the controller setting can be delivered. If a solar preheater has been installed
to an existing water heater installation, then all controllers must be disconnected and removed.
If this water heater is installed as part of a solar water heater system, the system can deliver water at
temperatures from 58°C up to 75°C and possibly higher depending upon the model of solar water heater
installed.

HOTTER WATER INCREASES THE RISK OF SCALD INJURY

This water heater can deliver water at temperatures which can cause scalding. Check the water temperature
before use, such as when entering a shower or filling a bath or basin, to ensure it is suitable for the
application and will not cause scald injury.
We recommend and it may be required by regulations that supplying hot water to an early childhood
centre,school,nursing home or a facility for young,aged,sick or disabled people.
An approved temperature limiting device supplying a fixed temperature of 45°C or less, to be fitted into the
hot water piping to the bathroom and ensuite when an 864 series water heater is installed
If no controllers are installed and the 864series preset outlet temperature setting has not be adjusted above
or is below 55°C There is no requirement in AS/NZS 3500.4 to fit a temperature limiting device if this water
heater is installed in other than an early childhood centre, school, nursing home or a facility for young, aged,
sick or disabled people.

EZ-LINK SYSTEM DUAL INSTALLATION

Two continuous flow 864 series gas water heaters installed in an Ez-Link
arrangement, when they are part of a circulated hot water flow and return system, can only have a Kitchen
controller installed
shown on page
shown on page
45, a pressure limiting valve must be fitted. The supply pressure
on page 9).
55°C
ABOUT YOUR WATER HEATER
5
maximum Kitchen controller
temperature setting 864 series
maximum Bathroom controller
temperature setting 864 series
minimum Kitchen and Bathroom
controller temperature setting
TM
system dual installation