Listing And Code Approvals; Appliance Certifi Cation; Glass Specifi Cations; Btu Specifi Cations - Quadra-Fire HUDBAY-INS Owner's Manual

Hudson bay insert direct vent gas appliance
Hide thumbs Also See for HUDBAY-INS:
Table of Contents

Advertisement

1 1

Listing and Code Approvals

A. Appliance Certifi cation
MODELS: Hudson Bay Insert
LABORATORY: Omni Test Laboratories, Inc. 061-S-51-5
TYPE: Direct Vent Gas Fireplace Heater
STANDARD: ANSI Z21.88-2002 • CSA 2.33-2002 • UL307B
CAN/CBA 2.17-M91
This product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
Manufactured Home or Mobile Home installation may
occur only after the home is site located and must conform
with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured
Home Installations, ANSI/NCSBCS A225.1, or Standard
for Gas Equipped Recreational Vehicles and Mobile
Housing, CSA Z240.4.
When installed, the appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70,
or the Canadian Electrical Code, CSA C22.1.
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass.
Replace glass only with 5 mm ceramic glass. Please con-
tact your dealer for replacement glass.
Note: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and
the CAN/CGA B149 Installation Codes in Canada.
C. BTU Specifi cations
Maximum
Minimum
Model
Input
(US or Canada)
BTU/h
BTU/h
Hudson Bay
42,000
28,000
Insert (NG)
Hudson Bay
40,500
31,000
Insert (LP)
*Maximum Vent Blower On
**Canada Only
4
Orifi ce
*Steady
Input
Size
State
(DMS)
Effi ciency %
.125
83.56
.076
85.39
Quadra-Fire • Hudson Bay Insert • 7008-115 Rev. H • 10/08
D. High Altitude Installations
Omni-Test Laboratories, Inc. listed gas appliances are
tested and approved without requiring changes for
elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500
feet in Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating
by changing the existing burner orifi ce to a smaller size.
Input rate should be reduced by 4% for each 1000 feet
above a 2000 foot elevation in the U.S.A. If the heating
value of the gas has been reduced, these rules do not
apply. To identify the proper orifi ce size, check with the
local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750ºC, shall be considered
non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that can ig-
nite and burn, whether fl ame proofed or not, or whether
plastered or unplastered shall be considered combustible
materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
**P.4
70-latest edition or the Canadian Electric Code CSA
%
C22.1.
• A 110-120 VAC circuit for this product must be protected
71.41
with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
74.45
locations such as in bathrooms or near sinks.
WARNING

Advertisement

Table of Contents
loading

Table of Contents