Listing And Code Approvals; Appliance Safety Certification; Appliance Emissions Certification; Btu & Efficiency Specifications - Quadra-Fire 4300 Series Owner's Manual

Wood appliance automatic combustion control
Table of Contents

Advertisement

1

Listing and Code Approvals

A. Appliance Safety Certification
Model: 43M-ACC-C & 43ST-ACC-C
Laboratory: OMNI Test Laboratories, Inc.
Report Number: 0061WS067S
Type: Listed Room Heater, Solid Fuel Type
UL1482-11 (R2015), ULC S627-00
Standard:
and (UM) 84-HUD,
Mobile Home Approved.
B. Appliance Emissions Certification
Model: 43M-ACC-C & 43ST-ACC-C
Laboratory: PFS-TECO
Report Number: 19-538
Method 28 and 5G, and
Standard:
ASTM E2515
Can be found at:
www.quadrafire.com/about-us/epa-certification
This wood appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate
this wood appliance in a manner inconsistent with operating instructions in this manual.
NOTE: This installation must conform with local codes. In the absence of local codes you must comply with (UM) 84-HUD
and NFPA211 in the U.S.A. and CAN/CSA-B365 Installation Codes in Canada.
February 17, 2020
The 43M-ACC-C & 43ST-ACC-C
is Certified to comply with
2020 crib wood particulate
emission standards.
7037-802A
C. BTU & Efficiency Specifications
EPA Certification
Number:
EPA Certified
Emissions:
*LHV Tested Efficiency: 80.2%
**HHV Tested Efficiency: 74.2%
***EPA BTU Output: 12,200 to 36,800 / hr.
****Peak BTU/Hour
Output:
Vent Size: 6 inches
Firebox Size: 2.26 cubic feet
Recommended Log
Length:
Fuel
* Weighted average LHV (Low Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests in accordance with the
requirements of CSA B415.1. LHV assumes the moisture
is already in a vapor state so there is no loss in energy to
vaporize.
** Weighted average HHV (High Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests in accordance with the
requirements of CSA B415.1. HHV includes the energy
required to vaporize the water in the fuel.
*** A range of BTU outputs calculated using HHV
Efficiency and the burn rates from the EPA tests, using
Douglas Fir dimensional lumber.
**** A peak BTU out of the appliance calculated using
the maximum first hour burn rate from the High EPA Test
and BTU content of seasoned cordwood (8600) times
the efficiency.
Number: N/A
1.6 grams per hour
61,700
18 inches
Seasoned Cord Wood
(20% moisture)
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

43m-acc-c43st-acc-cDiscovery iii seriesDiscovery-iii-c

Table of Contents