7 7

Electrical Information

A. Recommendation for Wire
See Figure 7.1 for recommended maximum lead length
(two wire) when using wall thermostat/switch.
NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
B. Connecting to the Appliance
1. This appliance may be used with a wall switch, wall
mounted thermostat and / or a remote control
2. If using thermostat, use one compatible with a millivolt
gas valve system.
3. Follow parameters for locating thermostat (see individ-
ual thermostat instructions) to ensure proper operation
of appliance.
4. Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
5. Use the following chart for wire sizing.
Wire Size
16 gauge
18 gauge
20 gauge
22 gauge
Figure 7.1
6. Keep wire lengths as short as possible by removing
any excess wire length.
7. Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
8. Ensure the thermostat is mounted level for accurate
readings.
9. The thermostat should be mounted on an inside wall
and not in direct line with the appliance convection air.
10. If the thermostat is located too close to the appli-
ance, you may need to set the temperature setting
slightly higher to maintain the desired temperature
in your home.
14
Max. Length
65 feet
40 feet
25 feet
18 feet
Quadra-Fire • Hudson Bay Insert • 7008-115 Rev. H • 10/08
Do not connect this appliance to a thermostat serving
any other appliance.
Bedroom installation in Canada requires this appliance
to be connected to a thermostat.
WARNING
Shock hazard.
• This appliance is equipped with a three
This appliance is equipped with a three
pronged (grounding) plug for your protection
pronged (grounding) plug for your protection
against shock hazard and should be plugged
against shock hazard and should be plugged
directly into a properly grounded three prong
directly into a prop
receptacle. Do not cut or remove the ground-
ing prong from this plug.
C. Standing Pilot Ignition System Wiring
This appliance DOES NOT require 110 VAC supply for
operation. A wiring diagram is shown in Figure 7.2 on the
next page.
This appliance is equipped with a millivolt control valve.