Framing And Clearances; Selecting Appliance Location; Clearances To Combustibles - Quadra-Fire HUDBAY-INS Owner's Manual

Hudson bay insert direct vent gas appliance
Hide thumbs Also See for HUDBAY-INS:
Table of Contents

Advertisement

3 3

Framing and Clearances

Note:
• Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (see fi gure 3.1).
B. Clearances to Combustibles
C
Hudson Bay Insert
Underneath bottom of appliance to combustibles: 3/8 in. (10 mm)
16 in. (406 mm) front floor protection required 0 in. to 2-1/2 in. (64 mm) below bottom of appliance. (1/2 in. of "k" = .84)
No floor protection needed if 2-1/2 in. (64 mm) or greater from bottom of appliance.
Figure 3.1
6
To 8 in. (203 mm ) Deep mantel:
14 in. (356 mm) From top of insert
B
D
Model
Inches
Millimeters
Quadra-Fire • Hudson Bay Insert • 7008-115 Rev. H • 10/08
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffi c areas.
NOTE: For actual appliance dimensions refer to Sec-
tion 12.
16 in. (406 mm)
HEARTH
A
B
14
11
12
356
279
305
WARNING
A
1-1/2 in. (38 mm)
C
D
7
178