30
CAUTION
PLUG-IN
3V TRANSFORMER
LOW VOLTAGE
FLAME SPARKER/
SEE NOTE 1
HIGH
TEMP
IGNITION
SWITCH
MODULE
(3V)
VALVE
LOW VOLTAGE
SEE NOTE 1
GROUND
NEUTRAL
REMOVE THESE CONNECTORS
TO WIRE SWITCHES
OPTIONAL
YLW
WALL
SWITCH
OPTIONAL
REMOTE
CONTROL
REMOVE THESE CONNECTORS
TO WIRE REMOTE
Figure 24. Intermittent Pilot Ignition Wiring Diagram
Heat & Glo • CFX-CRESCENT • 705-900 Rev. P • 12/07
Optional Accessories
Optional remote control kits require that 110-120
VAC be wired to the fireplace junction box.
Wall Switch
A wall switch is provided and is required. Position
the wall switch in the desired position on the wall.
The wall switch is 110-120 VAC and requires
appropriate wire be used. A junction box should be
used for the wire connections. See wiring diagram
for details.
At the appliance connect the wire to the ON/OFF
switch pigtails.
LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DAN-
GEROUS OPERATION. VERIFY PROPER OPER-
ATION AFTER SERVICING.
SENSOR
FAN
REMOTE
CONTROL
HOT
BLK
RELAY
BRN
BRN
WHT
YLW
BLK
BLK
YLW
XFMR
PLUG IN
BLK
FAN
JUNCTION BOX
120 VAC
IGNITION
MODULE 3 VAC
ORG
GROUND TO
FIREPLACE
WHT
CHASSIS
BRN
HIGH LIMIT
SWITCH
BRN
TRANSFORMER
3 VAC
INTERMITTENT
PILOT
IGNITION
WHT
VALVE