Step 6 The Gas Supply Line - Heat & Glo Gas Fireplace CFX-Crescent Owner's Manual

Hearth and home technologies gas fireplace owner's manual
Hide thumbs Also See for Gas Fireplace CFX-Crescent:
Table of Contents

Advertisement

28
Step 6
The Gas
Supply Line
• At the gas line
access hole in the
outer casing, use
insulation to re-pack
the space around
the gas pipe.
• The gas line should
be installed by a
qualified service
technician.
Heat & Glo • CFX-CRESCENT • 705-900 Rev. P • 12/07
NOTE: Have the gas supply line installed in accordance
with local building codes by a qualified installer ap-
proved and/or licensed as required by the locality. (In
the Commonwealth of Massachusetts installation must
be performed by a licensed plumber or gas fitter).
NOTE: Before the first firing of the fireplace, the gas
supply line should be purged of any trapped air.
NOTE: Consult local building codes to properly size the gas
supply line leading to 1/2 inch (13 mm) hook-up at the unit.
This gas fireplace is designed to accept a 1/2 inch (13
mm) gas supply line. To install the gas supply line:
• A listed (and Commonwealth of Massachusetts approved)
1/2 inch (13mm) tee-handle manual shut-off valve and a
listed flexible gas connector are connected to the 1/2
inch (13mm) inlet of the control valve. NOTE: If substi-
tuting for these components, please consult local codes
for compliance.
• A 1/8 inch (3 mm) N.P.T. plugged tapping, accessible for
test gauge connection, should be provided for in the gas
supply line leading to the unit's shut-off valve.
• Remove the decorative door on the unit by pulling away
from the unit to release it from the clips on each side.
• Locate the gas line access hole in the outer casing of the
fireplace.
• Insert the gas supply line through the gas line hole, and
connect it to the shut-off valve.
• When attaching the pipe, support the control so that the
lines are not bent or torn.
After the gas line installation is complete, all connections must
be tightened and checked for leaks with a commercially-avail-
able, non-corrosive leak check solution. Be sure to rinse off all
leak check solution following testing.
WARNING: DO NOT USE AN OPEN
!
FLAME TO CHECK FOR GAS LEAKS.
USE WRENCH
ON SHUT-OFF VALVE
WHEN TIGHTENING
GAS LINE
MANUAL
SHUT-OFF
VALVE
FLEX
CONNECTOR
GAS
VALVE
Figure 23. Gas Supply Line